di Series

User/Software Manual

di Series

User/Software Manual

25 Years

25 Years

Since 1995

www.heroninstruments.com

Rev. 1.0

2020

Содержание barLog

Страница 1: ...dipperLog Series User Software Manual dipperLog Series User Software Manual 25 Years 25 Years Since 1995 www heroninstruments com Rev 1 0 2020...

Страница 2: ...stem Components 10 Instrument 10 Vented Non Vented Direct Read Cable 11 Customizable Cable Length 11 Accessories 13 Getting Started 14 Downloading dipperLog Software 14 Downloading dipperLog Software...

Страница 3: ...29 Logging Method Descriptions 30 Downloading Data to PC 30 Multiple Downloads 31 Cleaning and Maintenance 32 Overview 32 What to Expect From Your dipperLog Groundwater Data Logger 32 Selecting the Pr...

Страница 4: ...ssure Ranges 10m 30ft 14PSI 30m 100ft 43PSI 60m 200ft 85PSI 120m 400ft 171PSI Overpressure Rating 2X Factory Calibrated Range Operating Temperature 20 C to 80 C 5 F to 175 F Pressure Resolution FS 0 0...

Страница 5: ...rating Features Pressure Ranges 10m 30ft 14PSI 30m 100ft 43PSI 60m 200ft 85PSI 120m 400ft 171PSI Overpressure Rating 2X Factory Calibrated Range Operating Temperature 20 C to 80 C 5 F to 175 F Pressur...

Страница 6: ...atures Pressure Ranges 10m 30ft 14PSI 30m 100ft 43PSI 60m 200ft 85PSI 120m 400ft 171PSI Overpressure Rating 2X Factory Calibrated Range Operating Temperature 20 C to 80 C 5 F to 175 F Pressure Resolut...

Страница 7: ...t 14PSI 30m 100ft 43PSI 60m 200ft 85PSI 120m 400ft 171PSI Overpressure Rating 2X Factory Calibrated Range Operating Temperature 20 C to 80 C 5 F to 175 F Pressure Resolution FS 0 001 Battery Life Depe...

Страница 8: ...30m 100ft 43PSI Overpressure Rating 2X Factory Calibrated Range Operating Temperature 20 C to 80 C 5 F to 175 F Pressure Resolution FS 0 01 Battery Life Depending On Usage Up to 2 500 000 Readings Up...

Страница 9: ...2 and ISO 80601 2 56 NIST Traceability Operating Features Pressure Ranges N A Overpressure Rating 2X Factory Calibrated Range Operating Temperature 20 C to 80 C 5 F to 175 F Pressure Resolution FS 0 0...

Страница 10: ...ged or vented pressure sensor eliminates the effects of atmospheric pressure because the vent tube in the vented cable allows atmospheric pressure to be applied to the back of the sensor The units of...

Страница 11: ...nts To compensate your absolute measurements use your barLog files within the dipperLog Software Note Both styles of direct read cable allow communication while the logger is in the well Polyethylene...

Страница 12: ...og Software USB The dipperLog Software PN 5008 comes free with every dipperLog purchased The latest version of the dipperLog Software can be downloaded from www heroninstruments com Communication Cabl...

Страница 13: ...casing fence or pump house any solid surface The tapNtell provides an instant real time reading of water level and temperature with a tap of a finger SDI 12 The SDI 12 PN 5021 system enables the dippe...

Страница 14: ...Getting Started Downloading dipperLog Software 1 Insert provided Heron USB dipperLog Software can also be obtained from www heroninstruments com 2 Open USB Drive find dipperLog Software download file...

Страница 15: ...dipperLog Series User Software Manual 15 www heroninstruments com 905 628 4999...

Страница 16: ...16 www heroninstruments com 905 628 4999 Downloading dipperLog Software Continued 4 The dipperLog Software is now successfully downloaded...

Страница 17: ...ot so low that the pressure sensor range might be exceeded at the highest anticipated water level Refer to the diagram below to determine usable depth Verify Depth After the dipperLog on direct read o...

Страница 18: ...d Radius 5cm 2 Stabilization Time Following installation of a logger allow for about 10 minutes in ideal cases before taking data reading in order for the logger to stabilize Also the deployment cable...

Страница 19: ...er or one that is not on a mission the device setup tab will open automatically To start a new deployment fill out the provided form to set up the logger Job Number 5 Digits Numbers Letters to Represe...

Страница 20: ...ttom left hand corner Note If the logger was on a mission the empty fields will become populated with data If it is a new logger the device setup tab will automatically open Logger Information Logger...

Страница 21: ...s set to start immediately or on a delayed start Logger started on Indicates the date when the logger was started only if the logger is currently on a mission Memory Status shows your logger s availab...

Страница 22: ...e on the data reports page click the Download button in the top left of the screen The logger will begin to transfer its data into the dipperLog Software Once finished downloading the data the data wi...

Страница 23: ...our dipperLog was started before placement in well this option allows you to use that first recorded barometric pressure reading to compensate all subsequent data points This will not adjust your data...

Страница 24: ...ensity of seawater ranges over somewhat higher values which vary with proximity to shores rivers etc as well as with geographic location depth Representative average values are 1 026 1 028 Van Nostran...

Страница 25: ...arLog data to be used in compensation Select Open to import files Select Add under the dipperLog Files Navigate to location where downloaded data sets are saved Select dipperLog data to be compensated...

Страница 26: ...rks to the boxes and select Save on Computer to overwrite the previously uncompensated data file The compensated data will now display two additional columns of values Head of Water Pressure recorded...

Страница 27: ...he device value fields For above example 1 137 10 55 3 Select Sync to establish correct calibration factor This correction can be applied by activating the drift compensation on the Data Reports tab a...

Страница 28: ...been completed the data files in CSV format will be exported to the designated destination folder with no further input from you If data needed in Text format dipperLog must be downloaded and saved i...

Страница 29: ...are currently being displayed The selected dipperLog information will be displayed Selecting a new ID number from the list display will update the screen to display the new settings Logger ID Serial...

Страница 30: ...n Cable to your PC and the other end to the dipperLog or well head reader 3 Select Connect Loggers in the bottom left corner of the screen 4 If you have multiple loggers connected to multiple PC Commu...

Страница 31: ...y to be re deployed or return to Logger Information for further options Multiple Downloads If you have multiple dipperLogs connected and listed in the text box on your screen select Multiple Downloads...

Страница 32: ...so damage the sensor A temperature detector is used to accurately compensate for temperature changes within the range of 0 C to 50 C for the dipperLog line Your dipperLog will record pressure and temp...

Страница 33: ...ite is based on your monitoring environment In good quality freshwater like a municipal production well inspecting a dipperLog and taking manual readings may be done once a season whereas physical cle...

Страница 34: ...ore bought products designed for household use can also be used Suspended Solids High suspended solid loads may block the pressure transducer holes or clog the internal pressure cell To minimize this...

Страница 35: ...nits are determined by your computer settings and not the software if someone sends you a file of dipperLog data that they downloaded and saved in metric if your computer settings indicate imperial un...

Страница 36: ...xcel or some other third party software application to recreate it Q What operating systems is the software compatible with A The software will work on Windows 7 Windows 8 Windows 10 Note The software...

Страница 37: ...ly slow dipperLog Troubleshooting 1 Make sure your logger is properly connected to your computer If it is on a detachable cable consider removing it from the cable and attaching the PC Communication c...

Страница 38: ...ity 300 hours continual reading at 150 C 0 03 C Temperature Repeatability 8 Averages 0 0078 C Temperature cycling and hysteresis 8 Averages 0 0156 C Temperature sensor meets ASTM E1112 and ISO 80601 2...

Страница 39: ...ifetime Temperature Stability 300 hours continual reading at 150 C 0 03 C Temperature Repeatability 8 Averages 0 0078 C Temperature cycling and hysteresis 8 Averages 0 0156 C Temperature sensor meets...

Страница 40: ...me Temperature Stability 300 hours continual reading at 150 C 0 3 C Temperature Repeatability 8 Averages 0 01 C Temperature cycling and hysteresis 8 Averages 0 02 C Pressure Water Level Test Condition...

Страница 41: ...ature Stability 300 hours continual reading at 150 C 0 3 C Temperature Repeatability 8 Averages 0 01 C Temperature cycling and hysteresis 8 Averages 0 02 C Pressure Water Level Test Condition Typical...