di Series User/Software Manual
11
www.heroninstruments.com
905-628-4999
Vented Direct Read Cable
Vented cable
is used with the dipperLog to
record gauged measurements. The cable vent tube
allows atmospheric pressure to be applied directly to
the back of the sensor. There is no need for
barometric compensation using vented cable.
Vented/Non-Vented Direct Read Cable
Non-Vented Direct Read Cable
Non-vented cable
is used with the dipperLog
Tough+, 128+, 64+ and 32+ models to record
absolute measurements. To compensate your
absolute measurements, use your barLog files within
the dipperLog Software.
Note:
Both styles of direct read cable allow
communication while the logger is in the well.
Polyethylene Suspension Cord
High tensile polyethylene suspension cord can be
used to install non-vented data loggers, or barometric
loggers. Use the suspension cord as a part of the
Suspended Absolute Model of dipperLogs (no
communication while in-situ). Available in two
lengths: 75m/250ft or 300m/1000ft.
Note:
Can be easily cut to desired length
Customizable Cable Length
Standard Non-Vented Cable Lengths:
(2m/5ft), (5m/15ft), (10m/30ft), (15m/50ft), (30m/100ft), (45m/150ft), (60m/200ft), (75m/250ft),
(100m/300ft), (150m/500ft), (225m/750ft), (300m/1000ft)