DECLARATION OF COMPLIANCE
The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 2009/142 for the
gas part and with norm
2006/95/CE,
2004/108/CE
for the electric part. The installation must be done observing the norms
in force particularly concerning room ventilation and discharging gas emissions.
N.B.: The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our sales
conditions.
RANGE TECHNICAL DATA TABLE
MODELS
DIMENSIONS
cm
POWER SUPPLY
MAXIMUM
ABSORPTION A
MAXIMUM
POWER kW
POWER SUPPLY
CABLE (Silicone)
CF4-78ET
80x70x90
400V 3N 50/60 Hz
27,8
15,4
5x4 mm²
CFQ4-78ET
80x70x90
400V 3N 50/60 Hz
27,8
15,4
5x4 mm²
CFC4-78ET
80x70x90
400V 3N 50/60 Hz
27
15
5x4 mm²
CF6-712ETV
120x70x90
400V 3N 50/60 Hz
33
20,6
5x6 mm²
CFQ6-712ETV
120x70x90
400V 3N 50/60 Hz
33
20,6
5x6 mm²
CF6-712ET
120x70x90
400V 3N 50/60 Hz
33
22,5
5x6 mm²
CFQ6-712ET
120x70x90
400V 3N 50/60 Hz
33
22,5
5x6 mm²
CFV4-78ET
80x70x90
400V 3N 50/60 Hz
30,14
15,7
5x4 mm²
CFVQ4-78ET
80x70x90
400V 3N 50/60 Hz
30,14
15,7
5x4 mm²
CFVC4-78ET
80x70x90
400V 3N 50/60 Hz
29,28
15,3
5x4 mm²
CFV6-712ETV
120x70x90
400V 3N 50/60 Hz
30,67
20,9
5x4 mm²
CFVQ6-712ETV
120x70x90
400V 3N 50/60 Hz
30,67
20,9
5x4 mm²
INSTRUCTIONS FOR INSTALLATION
The data plate is on the front (see diagram in electric connection item) and has all the data necessary for the connection.
INSTALLATION
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishing, etc. , these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
LAWS, TECHNICAL RULES AND NORMS
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription, norms in force.
ELECTRIC CONNECTION
The appliance is supplied without the connection cable. To install the power supply cable, proceed as follows:
•
Disconnect the power supply.
•
Remove the bottom panel
•
Push the connection cable through the cable blocker, connect the conductor wires to the corresponding terminals in
the junction box and fix them into place.
•
Block the cable with the cable blocker, and reassemble the bottom panel. The earth wire must be longer than the
others so that if the cable blocker should break, it will disconnect after the tension wires.