Instruction manual for installation, maintenance and use
Gas Kettles PMK.G...
PMK.G-GB-07
Page
19 di 36
3.2.1. FILLING THE JACKET (MODELS PMKIG… .)
Warning! : The water level in the jacket must be checked each time before lighting.
Warning! : It is advisable to use softened water to fill the jacket!
−
Open the level tap on the front of the appliance.
−
Unscrew the filling cap on the safety valve unit. The latter is on the right of the
appliance surface (see figure “Size of appliance and position
of connections ”).
−
Reposition the tap (an external hole is available) on the
external pin of the relief valve.
−
This operation is required to prevent water bubbles from
forming in the jacket during water loading. Water bubbles
would not make it possible to reach a correct water level in the
jacket.
−
Fill with softened water (the capacity of the jacket is stated in the paragraph “Technical
data”).
−
When water flows out of the level tap, close it and screw back on the safety unit cap.