28
Finalizing the Installation
(for qualified installers only)
© Travis Industries
6/27/2019 - 1500
864 31K CF Aust
Rear Vent Configuration with Horizontal Termination (no vertical rise)
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
Optional 45° Elbow
Termination
See the charts below to
determine maximum vent
3 feet (0.915m)
0 feet
0 feet
4' max (1.22m)
• Exhaust Restrictor # 1 (stock)
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)
Vent with No 45° Elbow
3 feet (0.915m)
0 feet
0 feet
2' max (0.61m)
Vent with 1 45° Elbow
• Min. 4" (102mm) Horizontal Section
• Max. 24" (610mm) Horizontal
Section(s)
• Min. 4" (102mm) Horizontal Section
• Max.48" (1219mm) Horizontal
Section(s)
• Exhaust Restrictor # 1 (stock)
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)