![London Electronics Fusion-P Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/london-electronics/fusion-p/fusion-p_manual_1938464014.webp)
14
Button Functions- ‘Quick-Step’ - Page 3
Functions
Buttons Conditions
888888
Calibration lockout ON
Link terminals 7, 10 and 8
Reset Tare
Press buttons briefly
8888
8888
Calibration lockout OFF
8888
8888
Calibration lockout ON and
Link terminals 7 and 8
Calibration lockout ON
Link terminals 7 and 9
Serial Comms setup
Press both buttons briefly
Tare display to 0
Press button briefly. Display shows 0 and the
button LED will illuminate to show you are tared.
Valley & Peak (Max. & Min.)
Press button briefly, once for peak, next for
valley
.
tar.1
Calibration lockout OFF
Tare Storage
Press both buttons briefly, press OK once
Change with UP/DOWN button. OK=Accept
rEv.0
Calibration lockout OFF
Reverse / Mirror display
Press both buttons briefly, press OK 5x
Change with UP/DOWN button. OK=Accept
Содержание Fusion-P