TYPES OF OPERATIONS
Logicube ZXi-
10G™ User’s Manual
43
5.3.2.1.2 Hash Values
By default, this value will have 0s (zeros). If this is not changed, or no value is
entered, this will instruct the unit to hash the drive using the selected
algorithm in the previous step. The result of the hash will be used as the
expected value. If a value is entered, the unit will hash the selected drive and
verify the calculated hash with the value entered/edited.
To set the expected value, tap the
edit
icon. The on-screen keyboard will
appear, and the expected hash value can be set.
There is a
Clear All
button to easily clear all values.
5.3.2.1.3 LBA
The LBA icon will bring up the LBA settings screen. The user can adjust the
percentage or the number of blocks of the drive to hash and where to start the
hash. By default, the length is set to 100% (whole drive), and the starting
percentage is set to 0% (start of the drive).