19B
-
5
EXHAUST
Catalytic converter
K7J, and 710
19B
REMOVAL
Mount the vehicle on a lift.
Remove the engine undertray.
Slide out the oxygen sensor connector to remove it
from its support (as shown by the arrow).
Disconnect the oxygen sensor connector.
Cut the exhaust pipe using tool (Mot. 1199-01)
between the two cutting points (1).
Essential special tooling
Mot. 1199-01
Exhaust pipe cutter
Mot. 1495
22 mm oxygen sensor
removal / refitting soc-
ket - 1/2" square drive
and a 24 mm Allen key
Tightening torques
m
oxygen sensor
4.5 daNm
c a t a l y t i c c o nverter
mounting nuts
2.1 daNm
IMPORTANT
Catalytic converters contain ceramic fibres; these
are contained within a closed unit, and cannot be
dispersed. Drilling or cutting catalytic converters
is prohibited.