INSTALLATION TECHNICAL DATA
HIGH ELEVATION
SYSTEM DATA
For 0 - 2,000 feet altitude*
burner Inlet Orifices Sizes:
NAT 3.55
LPG 1.75
* Above 2,000 feet see national Code Orifice Chart
Input rating
NAT
LPG
50,000 btu/h
48,000 btu/h
Supply Pressure
NAT
LPG Universal
Minimum
1.54 kPa
2.49 kPa
Maximum
1.99 kPa
2.99 kPa
Manifold
NAT
LPG
Pressure.92" to 0.22kPa
1.0" 2.74" kPa
ORIFICE SIZES AT ALTITUDE
Note: If altitude is more than 500’ above listing on chart use orifice specified at next
higher altitude.
Example:
7250 ft use a 3.26
7650 ft use a 3.04
SEA
2000'
3000'
4000'
5000'
6000'
7000'
8000'
9000'
10,000'
LEVEL
NG
3.55
3.45
3.45
3.26
3.26
3.26
3.26
3.04
3.04
3.04
LPG
1.75
1.7
1.7
1.61
1.61
1.61
1.61
1.51
1.51
1.51
Содержание MAUI
Страница 25: ...P Public Spec Sheets MAUI Gas Fire Indtructions pdf 25 INSTALLATION DIAGRAM 13 ...
Страница 29: ...P Public Spec Sheets MAUI Gas Fire Indtructions pdf 29 INSTALLATION DIAGRAM 14 ...
Страница 36: ...P Public Spec Sheets MAUI Gas Fire Indtructions pdf 36 MAUI ZERO CLEARANCE DIAGRAM 16 ...
Страница 37: ...P Public Spec Sheets MAUI Gas Fire Indtructions pdf 37 MAUI ZERO CLEARANCE DIAGRAM 17 DIAGRAM 18 ...
Страница 38: ...P Public Spec Sheets MAUI Gas Fire Indtructions pdf 38 MAUI ZERO CLEARANCE DIAGRAM 19 DIAGRAM 20 ...