INSTALLATION
(1)
Optional wall thermostat installation
A wall thermostat may be installed. If desired, follow the wiring
diagram on page 25.
The thermostat is supplied by Logaire, which is an approved Millwolt
thermostat 250 – 75 Millwolt rated. Refer to page 25.
(2)
Optional remote control
An optional hand remote control kit for turning the unit On and Off is
available. Detailed instructions for the optional Remote Control are
included with the kit.
RECOMMENDED MAXIMUM LEAD LENGTH
(Two-Wire) when using wall thermostat (Millivolt)
Wire Size
Max. Length
14 ga
328 meters
16 ga
210 meters
18 ga
131 meters
20 ga
82 meters
22 ga
60 meters
ELECTRICAL GROUNDING INSTRUCTIONS
WARNING
This gas heater is equipped with a three-prong (grounding) plug for your
protection against shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the grounding prong
from this plug
Содержание MAUI
Страница 25: ...P Public Spec Sheets MAUI Gas Fire Indtructions pdf 25 INSTALLATION DIAGRAM 13 ...
Страница 29: ...P Public Spec Sheets MAUI Gas Fire Indtructions pdf 29 INSTALLATION DIAGRAM 14 ...
Страница 36: ...P Public Spec Sheets MAUI Gas Fire Indtructions pdf 36 MAUI ZERO CLEARANCE DIAGRAM 16 ...
Страница 37: ...P Public Spec Sheets MAUI Gas Fire Indtructions pdf 37 MAUI ZERO CLEARANCE DIAGRAM 17 DIAGRAM 18 ...
Страница 38: ...P Public Spec Sheets MAUI Gas Fire Indtructions pdf 38 MAUI ZERO CLEARANCE DIAGRAM 19 DIAGRAM 20 ...