INSTALLATION
VENTING
The freestanding and inbuilt are vented appliances and must be connected to a
chimney/flue in accordance with the installation codes.
For your safety this heater is equipped with a vent safety switch designed to sense
incorrect venting and reacts by shutting down the gas supply. This heat actuated
switch is located within the draft hood and will detect either a blocked chimney or
backdraft condition. The chimney switch must
never be by-passed or disconnected as
a hazardous or deadly condition can result.
FREESTANDER
The Maui Freestander must be installed with a B-vent flue system as approved for use
by Logaire. For cosmetic or aesthetic purposes a 150mm outer flue can be used as
long as an approved inner vent is installed. Fasten the B-vent to the exhaust collar on
the top of the stove. If desired use one MG” sheet metal screw but do not penetrate
the inner sleeve of the B-vent when tightening the screw.
Follow all venting manufacture’s requirements and local building codes. In cold
climates, we recommend the use of insulated B-vent, chase, and liners. For altitudes
above 2000 ft. we recommend that a minumum flue height of 3.7M be used. A wind
cap is recommended for wind turbulent sites when flue spillage is noted. (See page
21).
MODEL INBUILT
The Maui inbuilt must be installed witha B-vent flue system as approved for use by
Logaire with a liner running the full length of the chimney. A minimum flue hight of
3.6m is recommended. B-vent must be supported by a vent support – supplied by the
vent manufacturer.
The Logaire Insert incorporates its own internal draft hood so no additional external
draft hood is required. Periodically check that the vent is not blocked and a sufficient
draft is present when the unit is in operation. Refer to spillage test page 21.
INSTALLATION INTO EXISTING WOODSTOVE/SOLID FUEL
FLUE SYSTEM
Never connect the Maui Gas Fire to a chimney flue serving a separate solid-fuel
burning appliance.
1. Clean and inspect the existing solid fuel chimney.
2. If using B-vent for the entire installation pass the B-vent through the existing
solid fuel chimney. Support the B-vent from the solid fuel chimney top (not
the cap) using vent hangers available from your local vent supplier. Install a
trim collar where the B-vent enters the solid fuel chimney. Connect B-vent to
the spigot collar on the stove using one sheet metal screw.
Содержание MAUI
Страница 25: ...P Public Spec Sheets MAUI Gas Fire Indtructions pdf 25 INSTALLATION DIAGRAM 13 ...
Страница 29: ...P Public Spec Sheets MAUI Gas Fire Indtructions pdf 29 INSTALLATION DIAGRAM 14 ...
Страница 36: ...P Public Spec Sheets MAUI Gas Fire Indtructions pdf 36 MAUI ZERO CLEARANCE DIAGRAM 16 ...
Страница 37: ...P Public Spec Sheets MAUI Gas Fire Indtructions pdf 37 MAUI ZERO CLEARANCE DIAGRAM 17 DIAGRAM 18 ...
Страница 38: ...P Public Spec Sheets MAUI Gas Fire Indtructions pdf 38 MAUI ZERO CLEARANCE DIAGRAM 19 DIAGRAM 20 ...