11
3N1
INSTALLATION
!
General Instructions
Attention
– Make sure cables are not jammed, bent or stretched.
– Keep cables away from hot surfaces.
– Route cables in existing cable channels. If no cable channel is available, fix with cable ties to the ma-
chine’s stationary parts and avoid moving parts to touch cables.
– Do not block ventilation openings of SCU with cables. Allow air circulation.
Installation
SCU
Open SCU front door
The SCU is installed in the headstock at the right side of the Savio PC.
1. Add the SCU earth wire to the earth stud located at the right side in the SCU opening.
Put the ring tongue between a spring washer and washer. (see picture below)
2. Install the SCU. Use the four screws M6 x 20 DIN85 and finishing washers
3. Open the SCU connections cover (4 screws) to connect the cables that are routed to
the SCU backside.
Compact Flash
(Detail)