background image

 

Contents 

1.0 GENERAL ........................................................................................................................................... 3 

2.0 OPERATION ....................................................................................................................................... 3 

3.0 COMPONENTS .................................................................................................................................. 3 
4.0 INSTALLING THE CORREX

®

 POWER ANODE ................................................................................. 4 

4.1 INSTALLING THE Ti-ANODE ............................................................................................................. 5 

4.2 INSTALLING THE CORREX

®

 POWER ANODE BOX ........................................................................ 5 

4.3 CONNECTING MAINS POWER ......................................................................................................... 7 

4.4 BMS CONNECTIONS ......................................................................................................................... 7 

4.5 SWITCHING ON THE CORREX

®

 POWER ANODE ........................................................................... 8 

4.6 MAINTENANCE .................................................................................................................................. 8 

4.7 FAULT FINDING ................................................................................................................................. 9 

4.8 WIRING DIAGRAM ........................................................................................................................... 10 

 
 

Содержание AMP 200-18

Страница 1: ...alier Electric storage water heater range Installation Commissioning and Maintenance Instructions Installation manual_Cavalier Correx_February 2020 For Use With AMP200 9 AMP200 18 AMP200 36 AMP300 9 A...

Страница 2: ...4 0 INSTALLING THE CORREX POWER ANODE 4 4 1INSTALLING THE Ti ANODE 5 4 2INSTALLING THE CORREX POWER ANODE BOX 5 4 3CONNECTING MAINS POWER 7 4 4BMS CONNECTIONS 7 4 5SWITCHING ON THE CORREX POWER ANODE...

Страница 3: ...d The only check required is to ensure a green LED is illuminated on the Correx front cover 2 0 OPERATION The Correx system operates on a 230V 1ph 50Hz electrical supply and has a 10V output to a tita...

Страница 4: ...Philips screwdriver Small Philips screwdriver Thread sealant NOTE An impact wrench may be required to remove the magnesium anodes if using such a tool the appropriate PPE must be worn Isolate the unit...

Страница 5: ...nd drill hole in order to mount the control box Photo 3 3 Using the screws provided Item No 3 secure the Correx Power Anode Box to the unit 4 Refit the plastic cap surrounding the anode and connect th...

Страница 6: ...6 PHOTO 3 PHOTO 4 PHOTO 1 PHOTO 2 PHOTO 5...

Страница 7: ...nal power supply independent to the water heater Warranty will be void if the correx unit is not powered 4 5 BMS CONNECTIONS The Correx unit is supplied with a volt free relay this relay is normally o...

Страница 8: ...Check a solid green LED is showing on the front of the unit this indicates the unit is working correctly If a BMS connection is made to the unit see section 4 5 you must still check the LED Remove th...

Страница 9: ...5 1 FAULT FINDING Under normal operation the unit will display a solid green LED If the unit is in fault it will either show a flashing red LED or no LED at all Use the below chart for possible cause...

Страница 10: ...10 5 2 WIRING DIAGRAM...

Страница 11: ...________________________ __________________________________________________________________________________ __________________________________________________________________________________ _________...

Страница 12: ...12...