ⱥㄒ㸭(1*/,6+
6
Tank Joint
Tank Case Unit
Vacuum Button
Exhaust Port
Set the Tank Case Unit to the Tank Joint.
Push to fit the Tank Case Unit to the Tank Joint as shown in the figure, and turn the Tank Case
Unit to the right until it is firmly fixed.
Set up the compressor, and be sure to install an air filter, air regulator and air lubricator
(3-device set) between the compressor and the tool.
PREPARATION BEFORE USE
1
2
Air regulator
Air filter
Air lubricator
Spool Cap
Rotary Joint
ە
Always attach the tank case unit before use.
If you work without attaching the tank case unit, there is a risk that the mandrel of rivet that has been
cut is not discharged, and will be clogged inside exhaust pipe, causing a fault of the equipment.
Also, these mandrels may be ejected from the tool’s nosepiece during use and cause serious injury.
WARNING
ە
When you turn the Vacuum Button ON, air comes out of the Exhaust Port on the side of the
Tank Case Unit.
ە
The Exhaust Port can face to any of the 4 directions, so change the direction as your preference.
Note
ە
Adjust the drip-feed amount of the air lubricator to the minimum setting.
ە
If moisture enters inside of the unit, it may freeze in cold temperature or accelerate degradation
of O-rings and packings, resulting in malfunction of the unit. To avoid that, use an air dryer as
necessary in addition to an air filter, regulator and an air lubricator (3-device set).
ە
If you attach the Rotary Joint to the opposite side, remove the Spool Cap and exchange the
positions.
Note
ձ
ղ