5.00 Operation
5.10 Direct Operation
The below instructions apply to LED luminaires that are not directly coupled to a
switch.
- The LED luminaire will turn on and remain on while power is supplied.
- When power is removed, the LED luminaire will turn off and remain off.
- Control power supplied to light using an external switch
WARNING
LIGHT IS NOT INTENDED FOR UNINTERRUPTED USE.
PLEASE OPERATE USING A DUTY CYCLE TO PREVENT PERMATURE
FAILURE OF LUMINAIRE
5.20 Button Operation
The below instructions apply to LED luminaires with a button on the light housing and/
or equipped with an M12 connector cable that is connected to an external switch/button.
The switch/button controls light operation in the following manner:
- One Button Press: 2-minute on time. Light will turn on for 2 minutes and then turn
off. A second button press during the 2-minute time interval will shut the light off.
- Two Rapid Presses: 30 minute on-time. Light will turn on for 30 minutes and then
turn off. An additional press during the 30-minute time interval will shut the light off.
- Three Rapid Presses: Activates dimmer mode. The light will dim by 10% for every
additional button press until 10% output is reached. When light output reaches 10% of
maximum, each press of the button will increase output by 10% until maximum
output is reached.
- Press and Hold: Switch becomes momentary. The light will turn on and remain on
while the button is pressed. When the button is released, the light will turn off and
remain off.
6.00 Safety
- Do not look directly into light source – risk of eyesight damage.
- Use caution when touching housing body as heat is generated during operation.