3.00 Mechanical Installation
3.10 Sight Glass Types and Sizes Suitable for Mounting
- Circular weld-on sight glass fitting to DIN 28120: size DN 50 (3” view diameter) and
larger
- Circular ANSI bolt-on sight window: size 2” and larger
- Visual flow indicators: size 2” and larger
- Circular weld-neck sight glass fitting series MV: size DN 50 and larger
Smaller sizes require flange adapter
- Sanitary clamp connection series MetaClamp: size 1” and larger
3.20 Mechanical Installation – USL16
3.21 Mounting using Hinged Bracket
The mounting bracket is supplied with the LumiStar3000 LED USL16 luminaire.
Fix bracket to a blind hole drilled and tapped on the cover flange of the sight
glass using supplied M6 screw.
3.22 Mounting using Flange Adapter
Flange adapter mounting is required for DIN 11851 units in small sizes. Adapter
fits under the slotted cover nut of DIN 11851 unit. Place gasket between adapter
and glass. Tighten slotted cover nut. Place LumiStar3000 into adapter sleeve.
Tighten set screws to secure.
3.30 Mechanical Installation – USL36
The LumiStar3000 LED USL36 luminaire is designed for mounting to a circular male
upstand on the cover flange of a sight glass. This is commonly achieved using a
Metaclamp Type 80 USL36. An O-ring provides a seal to the sight glass.
3.31 Assembly to Sight Glass
Verify O-ring is in place on male circular upstand on sight glass. Place
LumiStar3000 body (lens side) over upstand. Tighten set screws to secure.
Sight glass assembly to vessel per manufacturer instruction.
Manual: 02-0157 - IOM
3
12/22
Содержание LumiStar 3000 LED