4.00 Electrical Installation
4.10 Supply Requirements
- Low Voltage: 24V (AC or DC)
- High Voltage: 110-240V AC
- Power: 40W
Recommended
- Electrical Isolation - Connect supply to separate branch circuit to
avoid potential interference from adjacent equipment.
4.20 Electrical Connection
WARNING
ELECTRICAL CONNECTIONS MUST BE MADE WITH NO POWER
SUPPLIED TO LIGHT. FAILURE TO DO SO COULD RESULT IN PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
5-pin M12 connector cable (3-meter length) is supplied with Luminaire. 24V
light is supplied with A-type cable. 110-240V light is supplied with B-type cable.
Connect cable to light. Connect free wires per guide below (Table 4.1).
Unit is internally wired ready for operation.
Table 4.1: Wiring Table
Brown
Blue
Gray/Green
Black
White
24V –
+Vin
-Vin
GND
Ext. Switch
Ext. Switch
External Switch
24V – No
+Vin
-Vin
GND
Connect to
Connect to
External Switch
White
Black
110-240V –
Ext. Switch
Ext. Switch
GND
Line
Neutral
External Switch
110-240V – No
Connect to
Connect to
GND
Line
Neutral
External Switch