background image

   

1.00  Warranty

L. J. Star warrants its LumiStar3000 LED Luminaires against defects in material and 
workmanship for a period of eighteen months from the date of shipment. L. J. Star will, 
at its option, repair or replace those products that fail to perform as specified with the 
following exceptions.

1.10   Exceptions

 

Luminaires that have been opened. These luminaires are sealed products and opening 
of the light housing will void any warranty of the product, expressed or implied.

 

Luminaires that have been subject to misuse, mishandling, misapplication, neglect 
(including, but not limited to improper maintenance), accident, or improper installation.

 

Luminaires that have been modified (including, but not limited to use of unauthorized 
parts or attachments), adjusted, or repaired by persons not authorized by L. J. Star.

1.20   Provisions

 

L. J. Star’s responsibility hereunder is limited to repairing or replacing the product 
at its expense. L. J. Star shall not be liable for loss, damage, or expense directly or 
indirectly related to the installation or use of its products, or from any other cause or for 
consequential damages. It is expressly understood that L. J. Star is not responsible for 
damage or injury caused to other products, building, property or persons by reason of 
the installation or use of its products.

 

This warranty is in lieu of any other warranty expressed or implied by any party other 
than L. J. Star. Repairs and/or replacements shall be at the sole discretion of L. J. Star 
based upon the terms and conditions.

2.00   Introduction

2.10  Important Note on Application

 

Sight glass luminaires are intended solely for mounting on sight glass fittings. Under 
no circumstances should these luminaires be used for sealing vessel openings. An 
appropriate sight glass fitting must be used at all times.

 

Luminaires must always be installed, connected, and serviced by persons who have 
been specially trained and authorized to do said work.

2.20  General Operating Conditions

 

Independent of internal pressure/vacuum in the vessel, LumiStar3000 LED luminaires 
are approved for use in ambient temperatures from -40ºC up to +80ºC at the cable 
entry.

 

For use in non-hazardous locations only.

Manual: 02-0157 - IOM 

2

 12/22

Содержание LumiStar 3000 LED

Страница 1: ...P O Box 1116 Twinsburg OH 44087 Phone 330 405 3040 Fax 330 405 3070 E mail view ljstar com Web Site www ljstar com LumiStar 3000TM LED Installation and Operating Instructions ...

Страница 2: ...es and Sizes Suitable for Mounting 3 20 Mechanical Installation USL16 3 21 Mounting using Hinged Bracket 3 22 Mounting using Flange Adapter 3 30 Mechanical Installation USL36 3 31 Assembly to Sight Glass 4 00 Electrical Installation 4 4 10 Supply Requirements 4 20 Electrical Connection 5 00 Operation 5 5 10 Direct Operation 5 20 Button Operation 6 00 Safety 5 7 00 Maintenance 6 Manual 02 0157 IOM ...

Страница 3: ...irectly related to the installation or use of its products or from any other cause or for consequential damages It is expressly understood that L J Star is not responsible for damage or injury caused to other products building property or persons by reason of the installation or use of its products This warranty is in lieu of any other warranty expressed or implied by any party other than L J Star...

Страница 4: ... sight glass using supplied M6 screw 3 22 Mounting using Flange Adapter Flange adapter mounting is required for DIN 11851 units in small sizes Adapter fits under the slotted cover nut of DIN 11851 unit Place gasket between adapter and glass Tighten slotted cover nut Place LumiStar3000 into adapter sleeve Tighten set screws to secure 3 30 Mechanical Installation USL36 The LumiStar3000 LED USL36 lum...

Страница 5: ... INJURY AND OR PROPERTY DAMAGE 5 pin M12 connector cable 3 meter length is supplied with Luminaire 24V light is supplied with A type cable 110 240V light is supplied with B type cable Connect cable to light Connect free wires per guide below Table 4 1 Unit is internally wired ready for operation Table 4 1 Wiring Table Brown Blue Gray Green Black White 24V Vin Vin GND Ext Switch Ext Switch External...

Страница 6: ...Press 2 minute on time Light will turn on for 2 minutes and then turn off A second button press during the 2 minute time interval will shut the light off Two Rapid Presses 30 minute on time Light will turn on for 30 minutes and then turn off An additional press during the 30 minute time interval will shut the light off Three Rapid Presses Activates dimmer mode The light will dim by 10 for every ad...

Страница 7: ...hown by moisture buildup on the interior of the lens Allow luminaire to cool prior to performing washdown procedures Failure to do so presents a risk of water intrusion due to induced vacuum from sudden cooling of the interior of the luminaire Do not open the luminaire to perform service In the event of a malfunction please contact L J Star to coordinate service ...

Страница 8: ......

Отзывы: