Changing abrasives
Grinding Machine SBM-L 1000+1500 G1S2 ALU MIX
60
6.2.8 Measuring
wear
After replacing an abrasive belt, always adjust the S-unit so that the wear
display is on "Zero".
If the upper and lower wear measuring device is on zero, a normal edge
rounding should be achieved.
If a heavy edge rounding is desired, a deviation can also be made.
Abb. 56:
Mechanical wear display
1 Wear display on bottom S-unit
2 Hand lever to apply display of lower wear measurement
3 Wear display on top S-unit
4 Lever for wear display
5 Base plate for upper abrasive belt
6 Base plate for lower abrasive belt
Both abrasive belts can be measured independently of one another.
Measuring the wear on the upper abrasive belt
To measure the upper abrasive belts, lift the lever (4) out of its interlock
and pull it back.
Place the base plate (5) onto the abrasive belt.
Read the wear on the wear display (3).
Bring the base plate (5) back into initial position.
Measuring the wear on the lower abrasive belt
To measure the lower abrasive belts, left the lever (2) out of its interlock
and move it downwards until the base plate (6) is on the abrasive belt.
Read the wear on the wear display (1).
Bring the base plate (6) back into initial position.