RAPID STORING OF ELECTRONIC KEYS (Max 4)
The first time the new product is switched on (when the battery
connection is restored), the led will remain off for 60 seconds.
During this time it is possible to insert the electronic keys by
following the procedure illustrated.
Restore the connection of the battery and insert the first key to
be stored into the receptacle within 60 seconds, followed by all
the remaining keys to be stored one after the other.
Successful memorisation of each individual key is confirmed by
means of one flash of the led. At the end of this stage, it is possible
to exit or continue with the customisation of the Override code.
SET-UP
+
EMERGENCY
KEY
For manual setting, proceed according to the following operating procedure:
13
FINAL CHECK
After the alarm control unit has been installed (and has been programmed), its status will be
‘disarmed’. The steps below must be followed; close the doors, bonnet, boot and windows, and
make sure you do not forget the original remote controls inside the vehicle.
1.
Lock the doors using the original remote control (arming the alarm system) and check that
the vehicle’s original direction indicators flash n
°
1 times
(vedi nota1)
.
2.
The LED will flash. Complete the following tests during the initial 25 sec. period of immunity:
a positive result will cause the direction indicators to flash once:
• open a door, the bonnet and the boot
• insert a hand in an open window and move it backwards and forwards with respect to the
position of the ultrasonic sensors installed.
Each time the direction indicators flash, the initial period of immunity will start again from zero.
3.
When the initial period of immunity is over, the LED will flash more slowly and a 25-sec alarm
cycle will result if an alarm is triggered: the siren will issue its characteristic modulated sound,
the direction indicators will flash
(vedi nota2)
and the horn, if connected, will sound according
to its setting.
4.
Unlock the doors using the original remote control
(vedi nota2)
and check that the vehicle’s
direction indicators flash n
°
9 times; the siren will emit one warning signal and the LED will
flash to indicate the alarm log: refer to the operating instructions for further information on
how to decode these indications.
INHIBITION OF ULTRASONICS
The ultrasonic protection can be neutralised by following the procedure below:
REPEAT FOR ALL THE KEY
TO BE MEMORIZED
+15 ON
MEM=1 FLASH
TIME
OUT
10
SEC.
ON
EXIT
1 BEEP
MAX 60 SEC.
OFF
+ 15 ON
+ 15 OFF
+ 15 ON
+ 15 OFF
MAX
20 SEC.
X 3
= 1 FLASH
= 3 BEEP
2 BEEP
2 BOOP
Nota1:
Non è possibile attivare il prodotto tramite il radiocomando d’origine con il
Blinker d’emergenza in funzione.
Nota2:
La disattivazione del prodotto durante la fase d’allarme è unicamente possibile
inserendo la chiave d’emergenza nel proprio ricettacolo.