CHECK IF ALL THE CONNECTIONS ARE PROPERLY
SEALED.
If there is everything in order, check the thermostat
settings (off position). Connect the cooler ´s plug to the
electrical network. Then use the dispense head, bump a
keg and pressure the keg up to 1.5-2.6bars and then by
dispense tap pull a drink. If there some water or
cleaning solution left , hold the tap until it will flow a
drink only. Set the thermostat to the required
temperature. If you use a cooler for soft drinks cooling,
set the thermostat hand-barrow to the level 5 only –
not more, otherwise the drinks could freeze in the
cooler loops and could damage the whole systém
inside the cooler.
FOR MODELS WITH IN BULIT AIR COMPRESSOR, THERE
IS PRESSURE SET AUTOMATICALLY (from 2.3 to 2.7).
12. Push the tube into the
fitting firmly (
about 1.5
cm
). The tube must be cut
straight to avoid any
imperfect connections. If
you can´t insert the tube
in, you need to moisten
the end.
How to work with the fittings:
13. Hold the gray ring
towards the body of the
fitting and pull out the
tube.
CAUTION:
If you don´t hold the gray
ring while pulling the
tube, the fitting will cut
even more into the tube.
Disconnection:
THE TUBE MUST NOT BE UNDER PRESSURE WHEN
DISCONNECTING !
the gray ring
6.
Environment protection.
Waste sorting.
This product must not be disposed of
with any household waste. Packaging
allows the recycling and reuse of used
products and packaging materials. Re-
use of recycled materials helps prevent
environmental pollution and reduces the
demand for raw materials. Local regula-
tions may provide for separate collection
of household appliances in local outlets
or the point of purchase.
10. The temperature of
the cooled beverages is
controlled manually by a
thermostat in the range
between 4°C to 10°C.
The thermostat has a
controller from1 to 7.
Temperature and setting:
0= switched off
č
.
1
=
max.
temperature
beverage
10
°
C
č
.
7
=
min.
temperature
beverage
4
°
C
11.
a power supply. If you are
using this cooler for
cooling non alcoholic
beverages, then set the
manual thermostat on
the front of the machine
to a 5 maximum
, other-
wise the machine might
freeze
or get damaged.
Then connect to
Electrical connection:
The machine has to be connected to a power supply
of 220-240V 50Hz with 16A circuit breaker. Power
plug circuit installation must comply with applicable
regulations DIN, EN and ISO. If the power cord is
damaged, it must be replaced by the manufacturer or
a qualified person in order to prevent dangerous
situations.