background image

8.

Problem

 Cause

How to f

ix it 

Beverage doesn't flow

The keg is connected
wrongly
Not enough air  pressure
(low pressure)

The water froze after
sanitation

Closed compensator

Check if the keg coupler is connected properly

Use a pump - pump air into the keg
CO2-check the pressure in the machine with inbuilt
compressor- turn on the switch

Switch off the machine and you have to wait until
beverage will start flowing again (it can takes a few
minutes or up to several hours)!

Move with the small lever on the compensator

Beverage isn't cooled
enough

Setting of thermostat is
not correct
Bad air circulation

The machine is
overheated

Turn the thermostat to number 7

Check if the plate of the condenser isn´t blocked

Put the machine in colder surroundings

The beverage 

shoots out

under high pressure

 

The pressure is too high 

Lower the pressure in the keg

The air compressor
doesn't switch on

Switch the button on the cooler
Turn the adjustment screw to the right 

(

Kprofi

 

models

).

Air compressor doesn't
switch off

Loose connections

Pull out the air tube and then insert again
Tighten the nuts on the keg coupler
With Kprofi models check the pressure on the
manometer  

Excessive beer  foaming

Lower the beverage temperature, turn the thermostat
to the right
Compensate the beverage flow capacity, move the
little lever of the compensator upwards

Fittings do not seal
properly

The tube is not inserted
correctly

Damage to the tube 

Pull out the tube, check for any sharp edges, 
and if there are, cut with knife

Pull out the tube and shorten 2cm

Before you call the service:

Содержание PYGMY 20

Страница 1: ...NS FOR USE FLOW TYPE CONTACT COOLER LINDR ENGLISH LINDR CZ s r o Cooling and dispensing systems Sadov 132 CZ 503 15 Nechanice Czech Republic Tel 495 447 239 l Fax 495 425 085 l E mail info lindr cz ww...

Страница 2: ...rt tools or other objects into the propeller fan CAUTION Never touch electrical components with wet or damp hands CAUTION To ensure the performance of the cooling unit never blocktheairinlet Beer disp...

Страница 3: ...k of the cooler is labelled with an AIR sign see connection A C 9 Connect the air supply ontotheplasticfitting F 5 8 x 8 mm or connect withbuilt incompressor 8 Insert the beverage tube 3 8 going from...

Страница 4: ...e 4 Plastic fitting F 5 8 x9 5mm 5 Plastic fitting F 5 8 x 8 mm 6 Plastic fitting Y 8x8x8mm 7 Beverage 8 ON OFF switch for the compressor Connection C Using a built in compressor to pressurize for mac...

Страница 5: ...6 6 5 5 7 8 8 1 Screw the plastic fittings onto the keg coupler seepicture5and6 page9 2 Insert thehose3 8and5 16intothetheplasticfittingsonthekegcoupler seepicture8and9 page9 3 Connect the hose 3 8 an...

Страница 6: ...e Disconnection THE TUBE MUST NOT BE UNDER PRESSURE WHEN DISCONNECTING the gray ring 6 Environment protection Wastesorting This product must not be disposed of with any household waste Packaging allow...

Страница 7: ...nitizing using a sanitizing bottle Unscrew the head from the sanitizing bottle and pour clean water inside Screw the head onto the sanitizing keg then connect the keg coupler and pressurize the samewa...

Страница 8: ...of the condenser isn t blocked Put the machine in colder surroundings The beverage shoots out under high pressure The pressure is too high Lower the pressure in the keg The air compressor doesn t swit...

Страница 9: ...YES 14 5 kg 16 4kg 35l h 19 7kg 1 55A 357W 50l h 50l h 90l h 40l h 40l h 70l h 26 8kg 29 3 kg 1 83A 2 18A 421W 501W YES 30 0kg 2 18A 501W 34 0kg 36 0kg 2 90A 3 20A 667W 735W KONTAKT 115 KONTAKT 115 K...

Отзывы: