Operating Instructions
Pump ZPU 08 ATEX
810-53711-1
Page 18 / 57
Rev.: 003
31/07/2017
2.24.
Explosion protection
Always behave so that fire and explosion hazards are avoided.
A written work approval from the operator is required prior to working in
potentially explosive areas.
There must be no indications that parts of the explosion protection are
missing or are not working. Should such indications become apparent,
switch off the machine and inform a superior without delay. Keep
unauthorized persons away.
Measures for explosion protection must never be deactivated, modified or
bypassed.
It is forbidden to bring in ignition sources such as sparks, open flames and
hot surfaces in potentially explosive areas.
Check the machine at regular intervals for damage which may represent
an ignition risk.
The ignition temperature of the lubricant must lie at least 50 K over the
maximum admissible surface temperature of the components.
Only use tools and clothing which are permitted for use in potentially
explosive areas (ESD).
Transport, installation, repairs and work on electrical components may only
be carried out, if it has been ensured that the atmosphere is not potentially
explosive.
Repairs or modifications to machines which are protected against
explosions may be carried out only by the manufacturer or by a workshop
recognized by a named institution and confirmed in writing. If the work is
not carried out by the manufacturer, the repairs must be approved by a
named expert and confirmed in writing. The repairs are to be marked by a
repair sign on the machine, stating the following:
o
Date
o
Company responsible for the work
o
Type of repair
o
If applicable, expert's code
Transport damages can result in the loss of the explosion protection. If
transport damages can be seen, do not assemble the machine or put it into
operation
Содержание ZPU 08
Страница 1: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 1 57 Rev 003 31 07 2017 ZPU 08 ...
Страница 52: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 52 57 Rev 003 31 07 2017 ...
Страница 53: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 53 57 Rev 003 31 07 2017 ...
Страница 54: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 54 57 Rev 003 31 07 2017 ...
Страница 55: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 55 57 Rev 003 31 07 2017 ...
Страница 56: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 56 57 Rev 003 31 07 2017 ...
Страница 57: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 57 57 Rev 003 31 07 2017 ...