Parameters, Survey
DIP-switch combinations
DIP switch
Lubrication
Scheme
SW 1 SW 2 SW 3 SW 4 System / function
Versions Parameter
default
0 no
stroke
monitoring
6661c06
0
0
0
0
PMA
1 with
stroke
monitoring
0
no metering device and without cycle counter
1
with one metering device and without cycle counter
2
with one metering device and with cycle counter
3
with two metering devices and without cycle counter
6665c06
1
0
0
0
Progressive
4
with two metering devices and with cycle counter
0
EMU without monitored metering device 1)
1
EMU with monitored metering device 1)
2
SU without monitored metering device 2)
3
SU with monitored metering device 2)
4
3ZWV without monitored metering device 3)
6663c06
0
1
0
0
Two-line
5
3ZWV with monitored distributor 3)
0
with one pressure switch
6667c06
1
1
0
0
Centro-Matic
®
1
with two pressure switches
6662c06
0
0
1
0
COBRA
0 standard
setting
0
no metering device and no cycle counter, clock-pulsed
1
with metering device and no cycle counter, clock-pulsed
2
with metering device and cycle counter, clock-pulsed
3
no metering device, no cycle counter, not clock-pulsed
4
with metering device and cycle counter, not clock-pulsed
6666c06
1
0
1
0
Spray lubricating
system
5
with metering device and cycle counter, not clock-pulsed
6664c06
0
1
1
0
Test mode
6668b06
1
1
1
0
Configuration
mode
1)
EMU – electronic change-over control
2)
SU – pressure-controlled change-over control
3)