Subject to modifications
User Manual
LMC 1
9.3EN-98001-A07
Page 18 of 36
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Progressive systems, continued
Operation
Commissioning
6668b06
Fig. 14
DIP switch – configuration mode
6613m06
Fig. 15
Operating panel
a -
“
UP
“ key
b -
“
DOWN
“ key
6001a02
NOTE
“RESET“ as hold function:
You can interrupt the running lubrication
time by pressing the „RESET“ key
(> 2 sec.). The pause time starts from the
beginning.
6001a02
NOTE
„RUN“ to trigger additional lubrications:
You can interrupt the running pause time
by pressing the “RUN“ key (> 2 sec.). The
lubricating time starts from the beginning.
6001a02
NOTE
As soon as you press the "UP" key (pos. a,
Fig. 15) outside of the configuration mode,
the actual rest of the expired pause time is
shown in the display.
Parameter default
Â
Set the DIP switches (see view Fig. 2, page 6) as shown
in Fig. 14:
“1-1-1-0“ (SW1 ON - SW2 ON - SW3 ON - SW4 OFF)
Â
Select from the following versions to set the parameter
defaults in your progressive system:
- no metering device and no cycle counter ……..
0
- with one metering device and no cycle counter
1
- with one metering device and cycle counter....
2
- with two metering devices, no cycle counter
3
- with two metering devices and cycle counter...
4
6001a02
NOTE
The version number setting (0 - 4) is
shown in the LMC 1 display and is made
using the UP & DOWN keys on the
operating panel (see pos. a & b, Fig. 15).
Â
Complete your selection (0 - 4) with the ENTER key
(Fig. 15).
If you do not acknowledge your selection with ENTER, the
standard value of “0“ is automatically set.
Selecting the lubrication system
Â
First switch SW1 to SW3 to “1-0-0“
(ON-OFF-OFF).
Then set the right-hand DIP switch (SW4) to ON (Fig. 16).
6665b06
Fig. 16
DIP switch: progressive systems - settings
Â
After that, switch SW4 back to OFF (Fig. 17).
6665c06
Fig. 17
DIP switch: progressive systems – ready for operation
The standard settings to control your progressive system are
now complete and the system is ready for operation.
Please refer to page 19 for possible parameter adaptations.