![Lincoln LMC 1 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/lincoln/lmc-1/lmc-1_user-manual_1917670030.webp)
Subject to modifications
User Manual
LMC 1
9.3EN-98001-A07
Page 30 of 36
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
COBRA chain-lubrication systems, continued
Operation
Commissioning
6613m06
Fig. 32
Operating panel
a -
“
UP
“ key
b -
“
DOWN
“ key
6001a02
NOTE
“RESET“ as halt function:
You can interrupt the running lubrication
time by pressing the “RESET“ key
(> 2 sec.). The next pause cycle starts from
the beginning.
6001a02
NOTE
„RUN“ to trigger additional lubrications:
You can interrupt the running pause cycle
by pressing the “RUN“ key (> 2 sec.). The
lubricating time starts from the beginning.
6001a02
NOTE
As soon as you press the "UP" key (pos. a,
Fig. 32) outside of the configuration mode,
the actual rest of the expired pause cycle is
shown in the display.
Parameter default
6001a02
NOTE
No parameter defaults can be set for
COBRA chain-lubrication systems.
The standard setting “0“ applies.
Selecting the lubrication system
Â
First switch SW1 to SW3 to “0-0-1“
(OFF-OFF-ON).
Then set the right-hand DIP switch (SW4) to ON (Fig. 33).
6662b06
Fig. 33
DIP switch: COBRA chain-lubrication systems - settings
Â
After that, switch SW4 back to OFF (Fig. 34).
6662c06
Fig. 34
DIP switch:
COBRA chain-lubrication systems – operating mode
The standard settings to control your COBRA chain-
lubrication system are now complete and the system is ready
for operation.