Description, continued
MENU Reference list
Centralized
Display
Navigation
LMC 1
lubrication system
menu item
Parameter
Section
Count value
Through key(s)
Factory setting
Through UP or DOWN key
ENTER + MENU
PMA systems
ENTER
1
c – rn
Number of lubrication cycles
1 to 9999 lubrication cycles
±
1 stroke
ENTER
1
c – PS
Number of pause cycles
1 to 9999 pause cycles
±
1 pause cycle
ENTER
10
c – bl
Number of chain links
1 to 9999 chain links
±
1 chain link
ENTER
Jumps back to the first parameter
RUN
Acknowledgment of the modifications carried out & return to the operating mode
ENTER + MENU
Progressive systems
ENTER
10 min.
t – PS
Pause time
1 min. to 99 h. and 59 min.
±
1 minute
ENTER
1
c – rn
1)
Number of metering device
cycles
1 to 99 metering device cycles
±
1 cycle
2 min.
t – rn
1)
Lubrication time
1 min. to 99 min. and 59 sec.
±
1 second
ENTER
2 Min.
t – MO
1)
Monitoring time
1 min. to 99 min. and 59 sec.
±
1 second
ENTER
Jumps back to the first parameter
RUN
Acknowledgement of the modifications carried out & return to the operating mode
ENTER + MENU
Two-line systems
ENTER
12 min.
t – MO
Monitoring time
1 min. to 99 min. and 59 sec.
±
1 second
ENTER
10 min.
t – PS
Pause time
1 min. to 99 h. and 59 min.
±
1 minute
ENTER
Jumps back to the first parameter
RUN
Acknowledgement of the modifications carried out & return to the operating mode
ENTER + MENU
Centro-Matic
®
systems
ENTER
2 min.
t – MO
Monitoring time
1 min. to 99 min. and 59 sec.
±
1 second
ENTER
10 min.
t – PS
Pause time
1 min. to 99 h. and 59 min.
±
1 minute
ENTER
10 sec.
t – od
Switch-off delay time
1 sec. to 99 sec.
±
1 second
ENTER
Jumps back to the first parameter
RUN
Acknowledgement of the modifications carried out & return to the operating mode
ENTER + MENU
COBRA chain lubrication systems
ENTER
10 sec.
t – cl
Cleaning time per nipple
1 sec. to 99 sec.
±
1 second
ENTER
1
c – rn
Number of lubrication cycles
1 to 9999 lubrication cycles
±
1 lubrication cycle
ENTER
1
c – PS
Number of pause cycles
1 to 9999 pause cycles
±
1 pause cycle
ENTER
10
c – bl
Number of chain links
1 to 9999 chain links
±
1 chain link
ENTER
Jumps back to the first parameter
RUN
Acknowledgement of the modifications carried out & return to the operating mode
ENTER + MENU
Spray systems
ENTER
10 Min.
t – PS
Pause time
1 min. to 99 h. and 59 min.
±
1 minute
ENTER
1
c – rn
1)
Number of metering device
cycles
1 to 99 metering device cycles
±
1 cycle
2 min.
t – rn
1)
Lubrication time
1 min. to 99 min. and 59 sec.
±
1 second
ENTER
2 Min.
t – MO
1)
Monitoring time
1 min. to 99 min. and 59 sec.
±
1 second
ENTER
10 sec.
t – od
Re-spraying-time
1 sec. to 99 sec.
±
1 second
ENTER
Jumps back to the first parameter
RUN
Acknowledgement of the modifications carried out & return to the operating mode
1)
Are displayed or hidden depending on the parameter default (see “DIP-switch combinations“, page 11) in the set-up mode