Lincoln Impinger 3262BWEC Скачать руководство пользователя страница 51

Impinger X2 –Operator Manual

 

51

LIMITED WARRANTY FOR COMMERCIAL PRODUCTS 
 
LIMITED WARRANTY

 

Lincoln Foodservice Products, LLC (“Lincoln”) warrants this

 

product to be free from defects in material and workmanship for a period of one (1) 

year from the date of purchase. 

During the warranty period, Lincoln shall, at Lincoln’s option, repair, or replace parts determined by Lincoln to be defective in material or 
workmanship, and with respect to services, shall re-perform any defective portion of said services. The foregoing shall be the sole obligation 
of Lincoln under this Limited Warranty with respect to the equipment, products, and services. With respect to equipment, materials, parts 
and accessories manufactured by others, Lincoln’s sole obligation shall be to use reasonable efforts to obtain the full benefit of the 
manufacturer’s

 

warranties. Lincoln shall have no liability, whether in contract, tort, negligence, or otherwise, with respect to non-Lincoln 

manufactured products. 

WHO IS COVERED

 

This Limited Warranty is available only to the original purchaser of the product and is not transferable.  

EXCLUSIONS FROM COVERAGE 

 

Repair or replacement of parts required because of misuse, improper care or storage, negligence, alteration, accident, use of 
incompatible supplies or lack of specified maintenance shall be excluded 

 

Normal maintenance items, including but not limited to, light bulbs, fuses, gaskets, O-rings, interior and exterior finishes,  
lubrication, conveyor belt, motor bushes, broken glass, etc. adjustments and calibrations for temperatures, speed and air flows 

 

Failures caused by improper or erratic voltages 

 

Improper or unauthorized repair 

 

Changes in adjustment and calibration after ninety (90) days from equipment installation date 

 

This Limited Warranty will not apply to any parts subject to damage beyond the control of Lincoln, or to equipment which has been 
subject to alteration, misuse or improper installation, accidents, damage in shipment, fire, floods, power changes, other hazards or acts 
of God that are beyond the control of Lincoln 

 

This Limited Warranty does not apply, and shall not cover any products or equipment manufactured or sold by Lincoln when such 
products or commercial equipment is installed or used in a residential or non-commercial application. Installations not within the 
applicable building or fire codes render this Limited Warranty and any responsibility or obligations associated therein null and void.  
This includes any damage, costs, or legal actions resulting from the installation of any Lincoln commercial cooking equipment in a non-
commercial application or installation, where the equipment is being used for applications other than those approved for by Lincoln.  

 

LIMITATIONS OF LIABILITY

 

The preceding paragraphs set forth the exclusive remedy for all claims based on failure of, or defect in, products or services sold hereunder, 
whether the failure or defect arises before or during the warranty period, and whether a claim, however instituted, is based on contract, 
indemnity, warranty, tort (including negligence), strict liability, implied by statute, common-law or otherwise , and Lincoln its servants and 
agents shall not be liable for any claims for personal injuries, incidental or consequential damages or loss, howsoever caused. Upon the 
expiration of the warranty period, all such liability shall terminate. THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF 
ALL OTHER WARRANTIES, WHETHER WRITTEN, ORAL, IMPLIED OR STATUTORY  NO IMPLIED WARRANTY OF 
MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE SHALL APPLY. LINCOLN DOES NOT WARRANT ANY PRODUCTS 
OR SERVICES OF OTHERS. 

REMEDIES

 

The liability of Lincoln for breach of any warranty obligation hereunder is limited to: ( i )  the repair or replacement of the equipment on which 
the liability is based, or with respect to services, re-performance of the services; or (ii) at Lincoln’s option, the refund of the amount paid for 
said equipment or services. 
Any breach by Lincoln with respect to any item or unit of equipment or services shall be deemed a breach with respect to that item or unit or 
service only 

WARRANTY CLAIM PROCEDURE

 

Customer shall be responsible to: 

 

Immediately advise the Dealer or Lincoln’s Authorized Service Agent of the equipment serial number and the nature of the problem. 

 

Verify the problem is a factory responsibility.  Improper installation or misuse of equipment, are not covered under this Limited 
Warranty. 

 

Cooperate with the Service Agency so that warranty service may be completed during normal working hours. 

 

Travel Time not to exceed two hours and mileage not to exceed one hundred (100) miles. 

GOVERNING LAW

 

Limited Warranty shall be governed by the laws of the state of Delaware, USA, excluding their conflicts of law principles. The United Nations 
Convention on Contracts for the International Sale of Goods is hereby excluded in its entirety from application to this Limited Warranty 
 
 
 
Lincoln Foodservice Products, LLC  
1111 North Hadley Road 
Fort Wayne, Indiana 46804 

USA 

www.lincolnfp.com  

Содержание Impinger 3262BWEC

Страница 1: ...ca Technical Support Hotline 800 678 9511 Telephone 260 459 8200 www lincolnfp com operator manual This document includes Safety Notices Specifications Installation Instructions Operating Instructions...

Страница 2: ...that the oven be placed under a ventilation hood to provide for adequate air supply and ventilation Minimum clearances must be maintained from all walls and combustible materials See spacing instruct...

Страница 3: ...a Lincoln Foodservice Products LLC Service Representative This service is required by Lincoln Foodservice Products LLC in order to assist the purchaser in proper start up of oven on site Please note t...

Страница 4: ...lish Australia G Spanish Mexico Latin America T Mandarin China H Portuguese Portugal U Restricted I Not Used V English Pacific Rim Korea J Danish Denmark W English Middle East K Dutch French Belgium X...

Страница 5: ...illimeters of Water Column 3 5 0 87 8 70 88 9 4 5 1 12 11 2 114 3 7 1 74 17 40 177 8 10 2 48 24 87 254 0 10 5 2 61 26 11 266 7 11 2 73 27 36 279 4 14 3 48 34 81 355 6 14 5 3 61 36 05 368 3 NOTE For pr...

Страница 6: ...Impinger X2 Operator Manual 6...

Страница 7: ...Impinger X2 Operator Manual 7...

Страница 8: ...Impinger X2 Operator Manual 8 FIGURE A Rev 4 05...

Страница 9: ...X2 Operator Manual 9 FIGURE B Rev 4 05 ANALOG CONTROL PANEL PUSH BUTTON CONTROL PANEL On Off Switch Display Panel Up Down Buttons Temperature Button Time Button TEMP 500 F HEAT TOP BELT 3 00 BOTTOM B...

Страница 10: ...ns are shipped in an upright or vertical manner resting on the fan box cover The shipping crate is 36 915 mm wide by 76 1930 4 mm tall The conveyors are in their normal position and a separate box con...

Страница 11: ...e it guards against transmission of strain to all utility connections 7 Have a factory authorized technician inspect the installation and perform the initial start up The Installation Report should be...

Страница 12: ...on a flat and level surface near the area where the oven will be installed 3 Remove any metal banding shrink wrap cardboard and other shipping material from the oven 4 Remove the following items from...

Страница 13: ...ach end of lower conveyor opening and attach with brackets to the Yoke Note Bolts should be finger tight to allow movement of pivot lock 7 Insert 80 Square Tube through Idle End and Drive End Yokes Id...

Страница 14: ...ections of Pivot Pipe must meet in middle of Square Tube inside oven Excess piping should extend out each end of Square Tube 9 Attach Securing Strap to each Yoke figure 1 Attach latch end of Securing...

Страница 15: ...ght is placed on the upper bake chamber 13 Raise the oven to the desired height and lower onto the stand or on top of the bottom oven in a stack configuration 14 Remove the Securing Straps Pivot Pipes...

Страница 16: ...ent or louvers Keep louvers and bottom of oven clean and free of restrictions Make sure enough space is allowed around the unit for maintenance and service access Do not block access to the manual gas...

Страница 17: ...32 per foot Using 36 Level level oven to 1 32 per foot Level by placing shims between the caster and the stand s base plate Level by placing shims between the caster and the stand s base plate NOTE Re...

Страница 18: ...et 4 An increase in gas pressure will often cause all gas fired appliances to operate more efficiently 5 Gas Pressure Conversion 1 0 Pound 16 Ounces 27 7 Inches Water Column WC E FLOW DUAL CONVEYOR OV...

Страница 19: ...d Pressure 3 5 WC 10 WC For Lincoln X 2 Ovens to provide optimum performance the burner must receive at least the minimum dynamic pressure with no more than the maximum dynamic pressure drop Dynamic p...

Страница 20: ...a double stack configuration is installed An electrical wiring diagram is located inside the control box cover We recommend that the gas and electric utilities be installed and in place well before th...

Страница 21: ...nch NPT and NOT exceed six 6 feet in length All gas line fittings connectors and valves must be American Gas Association design certified MASSACHUSETTS The minimum length of a flexible gas supply hose...

Страница 22: ...imum of 36 inches 914 4mm clearance from all surfaces A minimum clearance of 18 457mm on both sides of the oven may be required for service accessibility In case other cooking equipment is located on...

Страница 23: ...Gas Utility Connection UTILITY SERVICE AND MOUNTING PLATE LAYOUT SINGLE OVEN Front Panel Hinge Plate Gas Electrical Utility Connection FIGURE C1 Rev 2 03 Idle End Drive End Large Base Mounting Plates...

Страница 24: ...an Box Top Oven Base Mounting Plates 4 places Note Model 3240 has only 2 plates Short Base Stack Configuration Gas Electrical Utility Connection Bottom Oven Drive End Drive End Gas Electrical Utility...

Страница 25: ...oper ventilation according to local codes and the unique characteristics of each installation Because codes vary greatly from region to region it is impossible to offer a single recommendation for all...

Страница 26: ...r deck of a double deck installation The test must be performed with a smoke candle rated at less than 1000 CFM with duration of 30 seconds The candle must operate in 500 F 260 C temperatures The oven...

Страница 27: ...MINIMUM SPACING REQUIREMENTS FOR CANOPY STYLE HOOD CANOPY STYLE HOOD 6 6 6 153 mm Minimum Clearance from End of Each Conveyor to Edge of Hood Idle End Drive End CANOPY STYLE HOOD 6 Minimum 153 mm 1 M...

Страница 28: ...ext to the lower conveyor time controller Regardless of the fuse location on the control panel they are all 2 0 AMP and protect the following components F8 Two 2 amp fuse for the burner F7 Two 2 amp f...

Страница 29: ...itch off wait one 1 minute and then repeat steps 1 4 The amber light located in the upper left hand corner of the analog temperature control OR the red LED on digital temperature controls will illumin...

Страница 30: ...ature button The set point temperature will be displayed and the temperature may be increased or decreased by pressing the up or down arrows 5 To set the belt time press the time button The display wi...

Страница 31: ...stance if a pie is baking at 480 degrees F at a 7 30 bake time and the center is not completely done hold the temperature constant and increase the bake time to allow heat more time to penetrate to th...

Страница 32: ...the upper corners of the panel Release the latches and the door can be lifted out of its normal position to provide access to the bake chamber interior The single piece conveyors can then be removed f...

Страница 33: ...GEMENT process develops the high velocity air stream that draws super heated air from the heat source This air is directed through a plenum chamber to FINGERS which have hundreds of focused jetports t...

Страница 34: ...Impinger X2 Operator Manual 34 LABEL DEFINITIONS...

Страница 35: ...Impinger X2 Operator Manual 35 SCHEMATIC UNITED STATES CANADA MODELS WITH PUSH BUTTON CONTROL BOARD...

Страница 36: ...Impinger X2 Operator Manual 36 SCHEMATIC DIAGRAM MODELS 3262 2 3270 2 50 HZ WITH PUSH BUTTON CONTROLS...

Страница 37: ...31 501090EP Thermocouple Type J 72 370117 Terminal Block 405849EP Conveyor Belt 15 405830EP Conveyor Belt 30 508103EP Male Lovejoy Coupling 508120EP Female Lovejoy PART NUMBER U S CANADA PARTS 100192E...

Страница 38: ...240 2 60Hz 390085 Motor Conveyor 3262 2 3270 2 60Hz 370359 Reversing Switch Conveyor Motor 369432 Switch On Off 370364 Ground Lug 507712EP Pulley Motor BK40 390095 Thermocouple Type K 72 inch 369368 T...

Страница 39: ...Digital 390090 Control Conveyor 501070EP Air Pressure Switch 508202EP Fan Belt w BK 45 Pulley 390059 Pulley BK 45 Motor Main Fan 3HP 1 Phase 50 Hz Motor Main Fan 3HP 3 Phase 50 Hz 369575 Air Pressure...

Страница 40: ...6G1 Motor main fan 3HP 1 Phase 50 Hz Model Only Vendor 35V424Q013G1 Gates 6929 V Belt 21 32 x 29 Lincoln Part 390128 Motor main fan 3HP 3 Phase 50 Hz Model Only Vendor 35V426Y886G1 Baldor Motor P N M3...

Страница 41: ...9432 ELECTRIC UTILITY KIT UTILITY EXTENSION KIT INSTALLATION INSTRUCTIONS...

Страница 42: ...Impinger X2 Operator Manual 42 1 Attach two hanger clamps to oven back by unscrewing two oven back bolts Align clamps re insert bolts and tighten Steps 1 3 Step 4 10001614 Step 2 Steps 5 6...

Страница 43: ...Impinger X2 Operator Manual 43 3 Using clamp assembly attach conduit 2 Fish cord into conduit 293 cord inside 10001615 conduit CLAMP ASSEMBLY 10001614 2011033 2212002 100525011 2111001...

Страница 44: ...mpinger X2 Operator Manual 44 4 Attach conduit to the X2 oven drive end control box and attach wiring to terminal block 5 Drill holes and attach electrical box to idle end control box 10001617 4070542...

Страница 45: ...block 4070221 10001616 10001618 4000054 4070542 4000148 2802772 7004936 9002882 2212002 100525011 2111001 2011033 23513 located under label 2212002 100525011 2111001 2011033 2212002 100525011 2111001...

Страница 46: ...This page intentionally left blank...

Страница 47: ...Impinger X2 Operator Manual 47 9431 GAS UTILITY KIT UTILITY EXTENSION KIT INSTALLATION INSTRUCTIONS...

Страница 48: ...Impinger X2 Operator Manual 48 2 Attach gas pipe brackets to oven by unscrewing bottom oven back bolts Align gas pipe brackets re insert bolts and tighten Step 1 Step 2 10000693 Step 5 Step 3 Step 4...

Страница 49: ...X2 Operator Manual 49 3 Attach gas piping to X2 oven gas inlet 10001610 10001613 10001611 4 Attach piping to 80 pipe 10001609 2614011 2614006 Viewed from side of drive end 10001613 10001609 2614011 1...

Страница 50: ...CLAMP ASSEMBLY 10001614 855114 2212002 100525011 2111001 2021028 2111001 100525011 2212002 7 Using clamp assembly attach oven piping to gas pipe brackets 8 Tighten pipe union 10001611 Gas Utility Kit...

Страница 51: ...associated therein null and void This includes any damage costs or legal actions resulting from the installation of any Lincoln commercial cooking equipment in a non commercial application or installa...

Страница 52: ...Impinger X2 Operator Manual 52...

Отзывы: