![Lincoln Impinger 3262BWEC Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/lincoln/impinger-3262bwec/impinger-3262bwec_operators-manual_1917795005.webp)
Impinger X2 –Operator Manual
5
MODELS
Single Oven
Double Oven
Conveyor Number &
Belt Width per Oven
Model
Configure
Total
Conveyors
Configure
Total
Conveyors
Upper
Lower
C.F.
Unit Wt. (lbs.)
Ship Wt. (lbs.)
3262FWMC
Standard 2 Standard 4
2 ea. -
16”
1 ea. -
32”
160 1400
1500
3262TWAC
Upper
Belt
Split 3 Upper
Belt
Split 6
2 ea. -
16”
2 ea. -
16”
160 1400
1500
3262BWEC
Lower
Belt
Split 3 Lower
Belt
Split 6
2 ea. -
16”
1 ea. -
32”
160 1400
1500
3262SWIC
Both Belts Split
4
Both Belts Split
8
2 ea. -
16”
2 ea. -
16”
160 1400
1500
3270FWMC
Standard 2 Standard 4
1 ea. -
16”
1 ea. -
32”
160 1400
1500
3270TWAC
Upper
Belt
Split 3 Upper
Belt
Split 6
2 ea. -
16”
1 ea. -
32”
160 1400
1500
3270BWEC
Lower
Belt
Split 3 Lower
Belt
Split 6
2 ea. -
16”
2 ea. -
16”
160 1400
1500
3270SWIC
Both Belts Split
4
Both Belts Split
8
2 ea. -
16”
2 ea. -
16”
160 1400
1500
GAS PRESSURE CONVERSION CHART
Inches of
Water Column
KPa m-Bar
Millimeters of
Water Column
3.5 0.87
8.70
88.9
4.5 1.12
11.2
114.3
7 1.74
17.40
177.8
10 2.48
24.87
254.0
10.5 2.61
26.11
266.7
11 2.73
27.36
279.4
14 3.48
34.81
355.6
14.5 3.61
36.05
368.3
** NOTE: For proper operation, the gas valve requires a nominal inlet pressure of 7
inches of H
2
O for natural gas and 11 inches of H
2
O column for L.P. gas. A minimum
inlet pressure of 1.0 inch of H
2
O column above the manifold setting (NAT. manifold
3.5” H
2
O, L.P. manifold 10” H
2
O) must be maintained with no pressure drop from the
no load to full load condition. The maximum inlet pressure must be maintained at or
below ½ PSIG (14.5 inches H
2
O column). Refer to the chart on the left for pressure
conversions.
Electrical Supply for Australia:
Single Phase: 240 VAC, 50 Hz / 20 Amp; one neutral & one earth/ground.
Three Phase: 240/415 VAC / 20 Amp; three active, one neutral & one earth/ground.
All ovens require separate service and dedicated neutral.
NOTE: Do not install the (these) oven(s) in any area with an ambient temperature in
excess of 95°F / 35° C. Doing so will cause damage to the unit.
Содержание Impinger 3262BWEC
Страница 6: ...Impinger X2 Operator Manual 6...
Страница 7: ...Impinger X2 Operator Manual 7...
Страница 8: ...Impinger X2 Operator Manual 8 FIGURE A Rev 4 05...
Страница 34: ...Impinger X2 Operator Manual 34 LABEL DEFINITIONS...
Страница 35: ...Impinger X2 Operator Manual 35 SCHEMATIC UNITED STATES CANADA MODELS WITH PUSH BUTTON CONTROL BOARD...
Страница 36: ...Impinger X2 Operator Manual 36 SCHEMATIC DIAGRAM MODELS 3262 2 3270 2 50 HZ WITH PUSH BUTTON CONTROLS...
Страница 41: ...9432 ELECTRIC UTILITY KIT UTILITY EXTENSION KIT INSTALLATION INSTRUCTIONS...
Страница 46: ...This page intentionally left blank...
Страница 47: ...Impinger X2 Operator Manual 47 9431 GAS UTILITY KIT UTILITY EXTENSION KIT INSTALLATION INSTRUCTIONS...
Страница 52: ...Impinger X2 Operator Manual 52...