The oven is equipped with an automatic cool-down circuit. The fan(s) will continue to run for approximately 30
minutes after the fan switch is turned off to allow the oven to cool. This is a TIMED FUNCTION and will turn off
the blower motor automatically. DO NOT UNPLUG THE OVEN DURING THIS TIMED SHUT DOWN PERIOD
OR SERIOUS DAMAGE MAY OCCUR TO THE UNIT. Unplugging the unit during the timed cool-down period
will void the warranty.
OVEN START-UP INSTRUCTIONS (UNITS WITH ANALOG CONTROL BOARD)
1. Turn the oven
FAN
switch
“ON.”
2. Adjust the temperature controller set point to desired temperature.
3. Turn
the
BURNER
switch
“ON.”
4. Observe indicated temperature for one minute. The temperature should rise after
30 – 45 seconds
. A
slight
“ticking”
noise is normal during this time.
5. If the burner does not ignite, turn the burner switch off, wait one (1) minute and then repeat steps 1 – 4. The
amber light (located in the upper left-hand corner of the analog temperature control OR the red LED on
digital temperature controls) will illuminate when the temperature control is calling for heat.
6. After the burner fires, turn the
CONVEYOR
switch(es)
“ON.”
DO NOT
turn the conveyors
ON
until after the
burner has fired.
7. Adjust the conveyor belt speed by pressing either an
“up” or “down”
arrow until the desired time is
displayed.
8. Allow about 15 minutes for the oven to reach the temperature set point and begin cycling before beginning
to bake any products.
OVEN SHUT-DOWN INSTRUCTIONS (UNITS WITH ANALOG CONTROL BOARD)
THIS UNIT IS EQUIPPED WITH AN AUTOMATIC COOL-DOWN CIRCUIT. THE MAIN FAN WILL CONTINUE
TO RUN FOR 30 MINUTES AFTER THE OVEN’S FAN SWITCH IS TURNED TO THE OFF POSITION.
1. Turn
the
CONVEYOR
switch(es)
“OFF.”
2. Turn the burner switch
“OFF.”
3. Turn
the
FAN
switch
“OFF.”
4. The main blower fan will run for approximately 30 minutes after the fan switch has been turned to the
“OFF”
position.
Содержание Impinger 3262BWEC
Страница 6: ...Impinger X2 Operator Manual 6...
Страница 7: ...Impinger X2 Operator Manual 7...
Страница 8: ...Impinger X2 Operator Manual 8 FIGURE A Rev 4 05...
Страница 34: ...Impinger X2 Operator Manual 34 LABEL DEFINITIONS...
Страница 35: ...Impinger X2 Operator Manual 35 SCHEMATIC UNITED STATES CANADA MODELS WITH PUSH BUTTON CONTROL BOARD...
Страница 36: ...Impinger X2 Operator Manual 36 SCHEMATIC DIAGRAM MODELS 3262 2 3270 2 50 HZ WITH PUSH BUTTON CONTROLS...
Страница 41: ...9432 ELECTRIC UTILITY KIT UTILITY EXTENSION KIT INSTALLATION INSTRUCTIONS...
Страница 46: ...This page intentionally left blank...
Страница 47: ...Impinger X2 Operator Manual 47 9431 GAS UTILITY KIT UTILITY EXTENSION KIT INSTALLATION INSTRUCTIONS...
Страница 52: ...Impinger X2 Operator Manual 52...