Lincoln Impinger 3262BWEC Скачать руководство пользователя страница 1

Lincoln Foodservice Products, LLC 

1111 North Hadley Road 

Fort Wayne, Indiana  46804 

United States of America 

Technical Support Hotline: (800) 678-9511 

Telephone: (260) 459-8200 

www.lincolnfp.com 

 

operator manual  

This document includes: 

 
• Safety Notices 
• Specifications 
• Installation Instructions 
• Operating Instructions 

• Cleaning Instructions 
• Warranty Statement 
 
 

Revision:  E 
P/N:  2810311

 

Impinger

®

 Conveyor Oven 

Model Series X2 

 

Содержание Impinger 3262BWEC

Страница 1: ...ca Technical Support Hotline 800 678 9511 Telephone 260 459 8200 www lincolnfp com operator manual This document includes Safety Notices Specifications Installation Instructions Operating Instructions...

Страница 2: ...that the oven be placed under a ventilation hood to provide for adequate air supply and ventilation Minimum clearances must be maintained from all walls and combustible materials See spacing instruct...

Страница 3: ...a Lincoln Foodservice Products LLC Service Representative This service is required by Lincoln Foodservice Products LLC in order to assist the purchaser in proper start up of oven on site Please note t...

Страница 4: ...lish Australia G Spanish Mexico Latin America T Mandarin China H Portuguese Portugal U Restricted I Not Used V English Pacific Rim Korea J Danish Denmark W English Middle East K Dutch French Belgium X...

Страница 5: ...illimeters of Water Column 3 5 0 87 8 70 88 9 4 5 1 12 11 2 114 3 7 1 74 17 40 177 8 10 2 48 24 87 254 0 10 5 2 61 26 11 266 7 11 2 73 27 36 279 4 14 3 48 34 81 355 6 14 5 3 61 36 05 368 3 NOTE For pr...

Страница 6: ...Impinger X2 Operator Manual 6...

Страница 7: ...Impinger X2 Operator Manual 7...

Страница 8: ...Impinger X2 Operator Manual 8 FIGURE A Rev 4 05...

Страница 9: ...X2 Operator Manual 9 FIGURE B Rev 4 05 ANALOG CONTROL PANEL PUSH BUTTON CONTROL PANEL On Off Switch Display Panel Up Down Buttons Temperature Button Time Button TEMP 500 F HEAT TOP BELT 3 00 BOTTOM B...

Страница 10: ...ns are shipped in an upright or vertical manner resting on the fan box cover The shipping crate is 36 915 mm wide by 76 1930 4 mm tall The conveyors are in their normal position and a separate box con...

Страница 11: ...e it guards against transmission of strain to all utility connections 7 Have a factory authorized technician inspect the installation and perform the initial start up The Installation Report should be...

Страница 12: ...on a flat and level surface near the area where the oven will be installed 3 Remove any metal banding shrink wrap cardboard and other shipping material from the oven 4 Remove the following items from...

Страница 13: ...ach end of lower conveyor opening and attach with brackets to the Yoke Note Bolts should be finger tight to allow movement of pivot lock 7 Insert 80 Square Tube through Idle End and Drive End Yokes Id...

Страница 14: ...ections of Pivot Pipe must meet in middle of Square Tube inside oven Excess piping should extend out each end of Square Tube 9 Attach Securing Strap to each Yoke figure 1 Attach latch end of Securing...

Страница 15: ...ght is placed on the upper bake chamber 13 Raise the oven to the desired height and lower onto the stand or on top of the bottom oven in a stack configuration 14 Remove the Securing Straps Pivot Pipes...

Страница 16: ...ent or louvers Keep louvers and bottom of oven clean and free of restrictions Make sure enough space is allowed around the unit for maintenance and service access Do not block access to the manual gas...

Страница 17: ...32 per foot Using 36 Level level oven to 1 32 per foot Level by placing shims between the caster and the stand s base plate Level by placing shims between the caster and the stand s base plate NOTE Re...

Страница 18: ...et 4 An increase in gas pressure will often cause all gas fired appliances to operate more efficiently 5 Gas Pressure Conversion 1 0 Pound 16 Ounces 27 7 Inches Water Column WC E FLOW DUAL CONVEYOR OV...

Страница 19: ...d Pressure 3 5 WC 10 WC For Lincoln X 2 Ovens to provide optimum performance the burner must receive at least the minimum dynamic pressure with no more than the maximum dynamic pressure drop Dynamic p...

Страница 20: ...a double stack configuration is installed An electrical wiring diagram is located inside the control box cover We recommend that the gas and electric utilities be installed and in place well before th...

Страница 21: ...nch NPT and NOT exceed six 6 feet in length All gas line fittings connectors and valves must be American Gas Association design certified MASSACHUSETTS The minimum length of a flexible gas supply hose...

Страница 22: ...imum of 36 inches 914 4mm clearance from all surfaces A minimum clearance of 18 457mm on both sides of the oven may be required for service accessibility In case other cooking equipment is located on...

Страница 23: ...Gas Utility Connection UTILITY SERVICE AND MOUNTING PLATE LAYOUT SINGLE OVEN Front Panel Hinge Plate Gas Electrical Utility Connection FIGURE C1 Rev 2 03 Idle End Drive End Large Base Mounting Plates...

Страница 24: ...an Box Top Oven Base Mounting Plates 4 places Note Model 3240 has only 2 plates Short Base Stack Configuration Gas Electrical Utility Connection Bottom Oven Drive End Drive End Gas Electrical Utility...

Страница 25: ...oper ventilation according to local codes and the unique characteristics of each installation Because codes vary greatly from region to region it is impossible to offer a single recommendation for all...

Страница 26: ...r deck of a double deck installation The test must be performed with a smoke candle rated at less than 1000 CFM with duration of 30 seconds The candle must operate in 500 F 260 C temperatures The oven...

Страница 27: ...MINIMUM SPACING REQUIREMENTS FOR CANOPY STYLE HOOD CANOPY STYLE HOOD 6 6 6 153 mm Minimum Clearance from End of Each Conveyor to Edge of Hood Idle End Drive End CANOPY STYLE HOOD 6 Minimum 153 mm 1 M...

Страница 28: ...ext to the lower conveyor time controller Regardless of the fuse location on the control panel they are all 2 0 AMP and protect the following components F8 Two 2 amp fuse for the burner F7 Two 2 amp f...

Страница 29: ...itch off wait one 1 minute and then repeat steps 1 4 The amber light located in the upper left hand corner of the analog temperature control OR the red LED on digital temperature controls will illumin...

Страница 30: ...ature button The set point temperature will be displayed and the temperature may be increased or decreased by pressing the up or down arrows 5 To set the belt time press the time button The display wi...

Страница 31: ...stance if a pie is baking at 480 degrees F at a 7 30 bake time and the center is not completely done hold the temperature constant and increase the bake time to allow heat more time to penetrate to th...

Страница 32: ...the upper corners of the panel Release the latches and the door can be lifted out of its normal position to provide access to the bake chamber interior The single piece conveyors can then be removed f...

Страница 33: ...GEMENT process develops the high velocity air stream that draws super heated air from the heat source This air is directed through a plenum chamber to FINGERS which have hundreds of focused jetports t...

Страница 34: ...Impinger X2 Operator Manual 34 LABEL DEFINITIONS...

Страница 35: ...Impinger X2 Operator Manual 35 SCHEMATIC UNITED STATES CANADA MODELS WITH PUSH BUTTON CONTROL BOARD...

Страница 36: ...Impinger X2 Operator Manual 36 SCHEMATIC DIAGRAM MODELS 3262 2 3270 2 50 HZ WITH PUSH BUTTON CONTROLS...

Страница 37: ...31 501090EP Thermocouple Type J 72 370117 Terminal Block 405849EP Conveyor Belt 15 405830EP Conveyor Belt 30 508103EP Male Lovejoy Coupling 508120EP Female Lovejoy PART NUMBER U S CANADA PARTS 100192E...

Страница 38: ...240 2 60Hz 390085 Motor Conveyor 3262 2 3270 2 60Hz 370359 Reversing Switch Conveyor Motor 369432 Switch On Off 370364 Ground Lug 507712EP Pulley Motor BK40 390095 Thermocouple Type K 72 inch 369368 T...

Страница 39: ...Digital 390090 Control Conveyor 501070EP Air Pressure Switch 508202EP Fan Belt w BK 45 Pulley 390059 Pulley BK 45 Motor Main Fan 3HP 1 Phase 50 Hz Motor Main Fan 3HP 3 Phase 50 Hz 369575 Air Pressure...

Страница 40: ...6G1 Motor main fan 3HP 1 Phase 50 Hz Model Only Vendor 35V424Q013G1 Gates 6929 V Belt 21 32 x 29 Lincoln Part 390128 Motor main fan 3HP 3 Phase 50 Hz Model Only Vendor 35V426Y886G1 Baldor Motor P N M3...

Страница 41: ...9432 ELECTRIC UTILITY KIT UTILITY EXTENSION KIT INSTALLATION INSTRUCTIONS...

Страница 42: ...Impinger X2 Operator Manual 42 1 Attach two hanger clamps to oven back by unscrewing two oven back bolts Align clamps re insert bolts and tighten Steps 1 3 Step 4 10001614 Step 2 Steps 5 6...

Страница 43: ...Impinger X2 Operator Manual 43 3 Using clamp assembly attach conduit 2 Fish cord into conduit 293 cord inside 10001615 conduit CLAMP ASSEMBLY 10001614 2011033 2212002 100525011 2111001...

Страница 44: ...mpinger X2 Operator Manual 44 4 Attach conduit to the X2 oven drive end control box and attach wiring to terminal block 5 Drill holes and attach electrical box to idle end control box 10001617 4070542...

Страница 45: ...block 4070221 10001616 10001618 4000054 4070542 4000148 2802772 7004936 9002882 2212002 100525011 2111001 2011033 23513 located under label 2212002 100525011 2111001 2011033 2212002 100525011 2111001...

Страница 46: ...This page intentionally left blank...

Страница 47: ...Impinger X2 Operator Manual 47 9431 GAS UTILITY KIT UTILITY EXTENSION KIT INSTALLATION INSTRUCTIONS...

Страница 48: ...Impinger X2 Operator Manual 48 2 Attach gas pipe brackets to oven by unscrewing bottom oven back bolts Align gas pipe brackets re insert bolts and tighten Step 1 Step 2 10000693 Step 5 Step 3 Step 4...

Страница 49: ...X2 Operator Manual 49 3 Attach gas piping to X2 oven gas inlet 10001610 10001613 10001611 4 Attach piping to 80 pipe 10001609 2614011 2614006 Viewed from side of drive end 10001613 10001609 2614011 1...

Страница 50: ...CLAMP ASSEMBLY 10001614 855114 2212002 100525011 2111001 2021028 2111001 100525011 2212002 7 Using clamp assembly attach oven piping to gas pipe brackets 8 Tighten pipe union 10001611 Gas Utility Kit...

Страница 51: ...associated therein null and void This includes any damage costs or legal actions resulting from the installation of any Lincoln commercial cooking equipment in a non commercial application or installa...

Страница 52: ...Impinger X2 Operator Manual 52...