EN
www.weldline.eu
LINCOLN ELECTRIC IBERIA S.L.
Ctra. Laureà Miró 396-398,
08980 Sant Feliu de Llobregat (Barcelona)
- SPAIN
We thank you for your trust in our company by purchasing this equipment which will
provide you with complete satisfaction if you comply with its conditions for use and
maintenance.
CAUTION:
The company declines all responsibility in case of modification, addition of
components or subassemblies, or any transformation of the equipment carried out
by the customer or a thirdparty, without prior specific written agreement from the
company.
Arc welding and plasma cutting may be dangerous for the operator and persons close
to the work area. Read the operating manual and safety instructions W000261712.
See www.weldline.eu.
A) Maintenance / Troubleshooting
Before any internal verifications and repair work, make sure that the equipment is
separated from the electric installation by electrical isolation (by electrical isolation is
meant a group of operations designed to separate and keep the equipment de-energized).
At least every six months, you must check the proper condition of the insulation and
connections of the electric equipment and accessories such as plugs, flexible wires,
ducts, connectors, extension leads, partholders, electrode-holders, or torches...
Maintenance and repair work on the jackets and insulating ducts must be carried out
extremely carefully.
Have defective parts repaired by a specialist, or better still, have them replaced.
Routinely check the proper tightening and cleanliness of the electric connections.
B) Work-station
Use only electrode holders and torches which are perfectly insulated.
The operator must be insulated from the ground-surface and the workpiece (gloves,
safety shoes, dry clothes, leather apron, and so forth...).
Do not touch the electrode wire and the part (or the nozzle) simultaneously.
C) Protection
It is absolutely essential that your protect your eyes from blinding glare (glare of arc
invisible light and infrared and ultraviolet radiation).
The welding mask, without or with helmet, must always be equipped with a protective
filter whose gradation depends on the welding arc current intensity (EN 169 Standard).
Fumes emitted during welding operations may be dangerous. Use adequate protection
means (fumes extraction, ventiled masks...)
The Standard Range
WTT2
9V
17V
26V
Curent
Duty cycle 35%
110 A
135 A
180 A
Duty cycle 60%
80 A
100 A
130 A
Light alloy welding, reduce the duty cycle about 30%
Voltage class
L - 113 V
Gas flow
Mini : 7 l/mn - Maxi : 13 l/mn
Power connection
25 mm
2
25 mm
2
50 mm
2
Using electrodes
Ø 1.0 / 3.2 mm
Ø 1.0 / 3.2 mm
Ø 1.0 / 4.0 mm
Origin
equipment fitted
to the torch
Back Cap
Long
Long
Long
Long
Long
Long
Nozzle
Ø 10 mm
Ø 10 mm
Ø 12 mm
Electrode
Ø 1.6 L
Ø 2.0 L
Ø 2.4 L
Instructions for safety, use and maintenance
Safety instructions
WTT2 9V
WTT2 17V
WTT2 26V
WTT2
4 m
9V
W000278876
Connector 9 mm
V
S
17V
W000278880
Connector 9 mm
W10529-17-4V
Connector 13 mm
26V
W000278885
Connector 13 mm
N°8695-1197_Rev2_05/2018
Technical data
TIG manual torch with natural cooling
Gas connector change
®