background image

PsT 900
PsT 900

XS

Installation Instructions

LED Floodlight

PLED18-900-8

PATHFINDER

LED

Lighting the way

2020 Pled Australia Pty Ltd. All rights reserved. For informational purposes only

Содержание PsT 900

Страница 1: ...PsT 900 PsT 900XS Installation Instructions LED Floodlight PLED18 900 8 PATHFINDER LED Lighting the way 2020 Pled Australia Pty Ltd All rights reserved For informational purposes only...

Страница 2: ...RIALAPPLICATIONS THE PRODUCT HAS BEEN DESIGNED FOR LOW MAINTENANCE AND IS SELF CLEANING IN REGIONS WHERE ADEQUATE NATURAL PRECIPITATION OCCURS IN EXTREME HOSTILE ENVIRONMENTS HOWEVER ESPECIALLY REGION...

Страница 3: ...cipal Dimensions PS001_5Z_DR003B M6 x 16 ISO 7380 FL SS Screws x 4 PDM2I600 PS900 Driver Module PLED18 900 8 339 00 428 00 92 00 178 00 292 00 520 00 2020 Pled Australia Pty Ltd All rights reserved Fo...

Страница 4: ...rade 8 8 GThe unit is cooled by convection DO NOT Install with Gravity vector perpendicular to Fin Plane PLED18 900 8 80 00 12 00 20 00 36 00 72 00 Azimuth Pivot R264 00 0 Tilt 0 0 1 2 5 0 0 8 6 0 0 2...

Страница 5: ...ng 4 x M6 Flanged screws M6 x 16 ISO 7380 FL SS Screws PLED18 900 8 PDM2I60 PS900 Driver Module On Board Mounting 201 00 237 00 Choose pivot hole rotate driver module to desired position Torque retain...

Страница 6: ...otherwise the useful life expectancy will be severely degraded and the warranty rendered void To ensure compliance with this limitation sample measurements of driver case Tc must be taken post install...

Страница 7: ...polarity critical Continuous or momentary reverse polarity will irreparably damage the LED COB and void warranty PLED18 900 8 BROWN BLUE OUTPUT 1 BROWN BLUE OUTPUT 2 Control 1 Control 2 BROWN BLUE DR...

Страница 8: ...gic Negative logic Casambi enabled modules are equipped with the CBU ASR twin channel Bluetooth dimming controller built into the driver assembly Once connected the luminaire assembly will be visible...

Страница 9: ...external features on the heat sink body Luminaire orientation with 0 inclinometer set to 0 Elevation Adjustment Inclinometer Azimuth Reference Face PLED18 900 8 90 00 Torque trunnion Nuts to 107Nm Lu...

Страница 10: ...lux meter In areas sensitive to light pollution it is highly recommended to obtain accurate aiming data and set the luminaire accordingly Loosen trunnion nuts and bracket mounting bolt Rotate luminai...

Страница 11: ...cts of God such as lightning sandstorms or Solar Flare induced fluctuations in electrical power Products which have been modified or have had the identification label and or the tamper proof label alt...

Страница 12: ...ons CAUTION Drivers rely on convective air currents for cooling and must be mounted vertically with a minimum adjacent spacing of 50mm in a suitably ventilated enclosure 7 Driver enclosure temperature...

Отзывы: