![Lince 1873BOBBY-AM Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/lince/1873bobby-am/1873bobby-am_installation-operation-and-maintenance-manual_1917372014.webp)
LINCE ITALIA S.p.A.
LEDs fail to switch on
Check wiring connection
Check the presence of current
and if the voltage is between 9.5
and 16 Vdc
Make sure that Dip Switch 6 is
set to OFF
False alarms
The detector is not perpendicular
to the ground
Check if the lower detection area
is wider than your planning
Check if there are objects in mo-
vement in the detection area.
MW adjustment is set at maxi-
mum level
No detection, someti-
mes.
The Lower PIR is not properly
adjusted
MW adjustment is set at mini-
mum level
Continuous alarms of
MASK output
Medium-sized obstacles close to
the detector
Open the lid, disconnect the de-
tector (wait about 5 seconds), re-
power and close the lid immedia-
tely (within 10 seconds)
Red LED blinking
Check the detector’s power
supply
3. RICERCA DEI GUASTI E/O MALFUN-
ZIONAMENTI
3. TROUBLE SHOOTING
Trouble
Soluzione
I LED non si accendono
Verificare la correttezza dei col-
legamenti
Verificare la presenza ed il valore
dell’alimentazione
Verificare che il Dip Switch 6 sia
in posizione OFF
Falsi allarmi
Il rilevatore non è perpendicolare
al terreno
Il PIR basso è mal regolato, rag-
giunge distanze superiori a quel-
le desiderate
Oggetti in movimento nell’area
protetta (biancheria stesa, rami
di alberi)
Il trimmer della sensibilità della
MW è al massimo
A volte non rileva
Errata regolazione in particolare
del PIR basso
La sensibilità della MW è al mi-
nimo
Allarmi continui dell’u-
scita MASK
Ostacoli di medie dimensioni a
ridosso del rilevatore
Aprire il coperchio, disalimentare
il rilevatore (attendere circa 5 se-
condi), rialimentare e chiudere il
coperchio immediatamente (en-
tro 10 secondi)
Il LED rosso lampeggia
Verificare
la
tensione
di
alimentazione del rilevatore.