Required Components
• Aurora Pro
• RGB LED fixture
• Voltmeter
Method
1. Power Aurora Pro ON.
2. Measure voltage between the + and - terminals on the female connector at the
end of the light run.
3. Ensure the measured voltage is greater than the thresholds listed above.
4. Remove the last section of lights if the voltage is too low.
5. Add a Power Top-Up (5 A Power Top-Up and a Power-T) and reconnect lights.
6. Retest the end-of-line voltage to ensure it meets the threshold.
Approved Lamp Types
• Lamp type: LED 5050
• Lamp wattage: 1 W
• All RGB LED fixtures use LED 5050 as the lamp type.
Warning:
Please contact Limbic Media to use Aurora Pro with fixtures other than those
listed in the following table.
End of Line Voltage Thresholds
VEOL > 10 V
VEOL > 9 V
VEOL > 8 V
Globes
Triklit-style fixtures
Bistro Strings, Light Strings, Pebble Module Lights
End of line Voltage Threshold
Fixture Type
Measure End of Line Thresholds
Measure the end-of-line voltage to ensure light fixtures are receiving adequate
power.
Figs. 40-42: Measuring end-of-line voltage