IFS-10-PM programming & display unit

+/- Value 2

see 

+/- Value 1

-999999

999999

0

Units 2

see 

Units 1

0

12

0

Decimal Point 2

see 

Decimal Point 1

0

5

0

NOTE

Parameters marked with “2” in the name are applied to the input frequency 2
and used to show the value in the display mode 4.

NOTE

For some examples about the visualization of the values expressed in frequency,
speed, production rate, etc. please refer to the “7 - Example of an individual
scalable display”
 section on page 35.

MAN IFS-10-PM EN 1.1.odt

6 - IFS-10-PM parameters list

30/44

Содержание IFS-10-PM

Страница 1: ...save and load the parameters Suitable for the following models IFS 10 PM General Contents Preliminary information 7 1 Safety summary 8 2 Identification 10 3 Technical features 11 4 Electrical connecti...

Страница 2: ...on herein is subject to change without notice and should not be construed as a commitment by Lika Electronic s r l Lika Electronic s r l reserves the right to make all modifications at any moments and...

Страница 3: ...AL OPERATION mode 16 Display 1 Frequencies Hz 16 Display 2 Divergence 16 Display 3 Scaled Input 1 16 Display 4 Scaled Input 2 16 5 4 FACTORY SETTINGS mode 17 5 5 PROGRAMMING mode 18 5 5 1 IFS 10 PM me...

Страница 4: ...isor 2 29 Value 2 30 Units 2 30 Decimal Point 2 30 Unit Settings 31 Display Mode 31 Screen Light 31 Screen Saver 31 PIN Value 31 Touch Tones 31 Serial Settings 33 Unit Number 33 Serial Baud Rate 33 Se...

Страница 5: ...rom Display Memory 21 Load Data From Safety Unit 21 P PIN Value 31 Please Confirm 25 R Readback Error 38 Runtime Error 37 S Safety unit 19 Save Data To Display Memory 24 Save Data To Display Unit 24 S...

Страница 6: ...nt to highlight the parts of the text where information of great significance for the user can be found user must pay the greatest attention to them Instructions must be followed strictly in order to...

Страница 7: ...L switch settings Among the main features are touchscreen with intuitive navigation 1 54 OLED display 128 x 64 pixels simple parametrization of the safety unit editing saving and loading of parameter...

Страница 8: ...ing the device connect according to the explanation in the 4 Electrical connections section on page 14 in compliance with the 2014 30 EU norm on electromagnetic compatibility following precautions mus...

Страница 9: ...cal installation has to be carried out with power supply disconnected and stationary mechanical parts do not disassemble the unit do not tool the unit delicate electronic equipment handle with care do...

Страница 10: ...nd the serial number when reaching Lika Electronic for purchasing spare parts or needing assistance For any information on the technical characteristics of the product refer to the technical catalogue...

Страница 11: ...Please ensure an adequate ventilation and avoid all direct contact between the device and hot or aggressive gases and liquids Before installation or maintenance the unit must be disconnected from all...

Страница 12: ...rvoltages at the connections must be limited to values in accordance to the overvoltage category II For placement wiring environmental conditions as well as shielding and earthing grounding of the sup...

Страница 13: ...perators are self responsible Do not use abrasive fabrics or materials such as paper towels even though they are soft as they scratch the display Do not use chemical agents and products that are gener...

Страница 14: ...ectrically connects the IFS 10 PM to the safety unit For information on the mechanical installation refer also to the 3 3 Mounting the display unit on the IFS 10 safety unit section on page 12 After i...

Страница 15: ...ase the numeric value the number flashes The ARROW LEFT button either switches to the previous menu item or selects the previous position in the value to be edited the number flashes The ARROW RIGHT b...

Страница 16: ...parameter in the Main menu of the safety unit The value depends on the scaling and divergence parameter settings of the safety unit Display 3 Scaled Input 1 In this mode the input frequency of the sen...

Страница 17: ...arameters are set at the factory by Lika Electronic engineers to allow the operator to run the device for standard operation is a safe mode No data entry to the IFS 10 PM display unit is available in...

Страница 18: ...it Please select Display Unit to edit the IFS 10 PM display unit parameters and then press the OK button to confirm Edit Data Please select Edit Data to edit the IFS 10 PM display unit parameters and...

Страница 19: ...ta To edit already loaded parameters please select Use Loaded Data and then press the OK button to confirm See the 5 6 Load parameters section on page 21 Load Data From Safety Unit To load the current...

Страница 20: ...button to confirm See the 5 8 Save parameters section on page 24 Save Data To Display Memory To save the parameters of the IFS 10 safety unit on the flash memory of the IFS 10 PM display unit please s...

Страница 21: ...0 safety unit or the flash memory of the IFS 10 PM display unit To edit the already loaded parameters please select Use Loaded Data and then press the OK button to confirm Load Data From Safety Unit T...

Страница 22: ...f the display unit the following warning message will appear ATTENTION No Data In Flash 5 6 3 Loading the parameters of IFS 10 PM The Load Data From menu is only available for the parameters of the IF...

Страница 23: ...the arrow buttons The current value of the parameter appears on the display too After pressing the OK button the parameter can be edited By using the left right arrow buttons the cursor can be skipped...

Страница 24: ...please select Save Data To Safety Unit and then press the OK button to confirm Save Data To Display Memory To save the parameters of the IFS 10 safety unit on the flash memory of the IFS 10 PM display...

Страница 25: ...nu see on page 21 5 9 Entering the pin value Customarily the IFS 10 PM display unit is delivered without a PIN identification i e with PIN Value 0000 Thus the PIN Value request after initialization is...

Страница 26: ...f the IFS 10 PM display unit keypad the PIN must be entered and confirmed by pressing the OK button WARNING Should the individual PIN be forgotten or lost you can enter the emergency pin 6079 MAN IFS...

Страница 27: ...t Scaling for display 3 and 4 X Factor 1 1 999999 1 Divisor 1 1 999999 1 Value 1 999999 999999 0 Units 1 0 12 0 Decimal Point 1 0 5 0 X Factor 2 1 999999 1 Divisor 2 1 999999 1 Value 2 999999 999999 0...

Страница 28: ...t Edit Data Settings Parameter Group Parameter Min Max Default Unit Settings Display Mode 1 3 1 Screen Light 0 99 0 Screen Saver 0 999 1 PIN Value 0 9999 0 Touch Tones 0 1 1 Serial Settings Unit Numbe...

Страница 29: ...It set the divisor to be applied to the input frequency 1 before it is shown in the display mode 3 1 999999 1 Value 1 It sets the value to be added to subtracted from the input frequency 1 before it...

Страница 30: ...ed with 2 in the name are applied to the input frequency 2 and used to show the value in the display mode 4 NOTE For some examples about the visualization of the values expressed in frequency speed pr...

Страница 31: ...ED display 0 Display brightness minimum 99 Display brightness maximum 0 99 0 Screen Saver It sets the time expressed in minutes after which the screen saver is activated 0 screen saver OFF 1 screen sa...

Страница 32: ...unit Changes in the Screen Light or Screen Saver parameter values are effective immediately but they are lost if not saved see the 5 8 Save parameters section on page 24 MAN IFS 10 PM EN 1 1 odt 6 IF...

Страница 33: ...parity even stop bit 1 1 data bits 7 parity even stop bit 2 2 data bits 7 parity odd stop bit 1 3 data bits 7 parity odd stop bit 2 4 data bits 7 parity stop bit 1 5 data bits 7 parity stop bit 2 6 da...

Страница 34: ...programming display unit to the user s settings Using a baud rate higher than 9600 baud the duration of the initialization procedure will be shortened MAN IFS 10 PM EN 1 1 odt 6 IFS 10 PM parameters l...

Страница 35: ...Save parameters section on page 24 The calculation of an individual scalable display is made as follows The measuring unit see Units 1 Units 2 as well as the number of decimal digits see Decimal Poin...

Страница 36: ...nformation on the parameters of the Input Scaling for display 3 and 4 group please refer to page 29 For any information on the Display 1 Frequencies Hz and the Display 3 Scaled Input 1 Display 4 Scale...

Страница 37: ...ht next to the error message in the status line of the display All H values and their related error explanations are listed in the User s manual of the safety unit see the Error detection section EXAM...

Страница 38: ...invoked to appear if corrupted data is found while saving data to or loading data from the flash memory Corrupted data cannot be loaded from the flash memory and used it needs to be saved again Readb...

Страница 39: ...itive touch fields key tones switchable to mute Data memory Storage medium Data retention Flash EEPROM 1 000 000 cycles Housing Material Mounting Dimensions Protection class Weight front polycarbonate...

Страница 40: ...1 Divisor 1 1 Value 1 0 Units 1 0 Decimal Point 1 0 X Factor 2 1 Divisor 2 1 Value 2 0 Units 2 0 Decimal Point 2 0 Unit Settings Display Mode 1 Screen Light 0 Screen Saver 1 PIN Value 0 Touch Tones 1...

Страница 41: ...This page intentionally left blank...

Страница 42: ...This page intentionally left blank...

Страница 43: ...This page intentionally left blank...

Страница 44: ...05 2016 First issue 01a 02a 1 1 05 05 2022 USB information removed address setting changing the scaled input new parameters added 02b 02c 03a 03b 04a Lika Electronic Via S Lorenzo 25 36010 Carr VI Ita...

Отзывы: