Serial Settings
Parameter
Min
Max
Default
Unit Number
An identification number between 11 and 99 can
be assigned to the device (default setting = 11).
Unit numbers must not contain any “0“ because
such numbers are used for group- or bulk-
addressing.
11
99
11
Serial Baud Rate
It allows to set the serial transmission speed
(baud rate). Available options are:
0
9 600
Baud
1
4 800
Baud
2
2 400
Baud
3
1 200
Baud
4
600
Baud
5
19 200
Baud
6
38 400
Baud
7
56 000
Baud
8
57 200
Baud
9
76 800
Baud
10
115 200
Baud
0
10
0
Serial Format
It allows to set the format of the serial data.
Available options are (default value in bold):
0
data bits = 7 parity = even stop bit = 1
1 data bits = 7 parity = even stop bit = 2
2 data bits = 7 parity = odd stop bit = 1
3 data bits = 7 parity = odd stop bit = 2
4 data bits = 7
parity = ---
stop bit = 1
5 data bits = 7
parity = ---
stop bit = 2
6 data bits = 8 parity = even stop bit = 1
7 data bits = 8 parity = odd stop bit = 1
8 data bits = 8
parity = ---
stop bit = 1
9 data bits = 8
parity = ---
stop bit = 2
0
9
0
Serial Init
This parameter allows to set the baud rate for the
transmission of the initialization values to the OS
software tool or to the IFS-10-PM programming
and display unit.
0: The initialization values will be transmitted at
9600 baud. After initialization the unit operates
again according to the user's settings.
1: The initialization values will be transmitted
using the user defined baud rate. After
initialization the unit operates again according
0
1
0