IFS-10-PM programming & display unit
8 - Error Messages
Error and status messages will be shown in the info line of the IFS-10-PM
display unit.
8.1 Error messages from the Safety Unit
Runtime Error
Initial Error
When an error message (
) is invoked from the
safety unit, a hexadecimal value (H) appears right next to the error message in
the status line of the display. All (H) values and their related error explanations
are listed in the “User's manual” of the safety unit (see the “Error detection”
section).
EXAMPLE
The hexadecimal number of the error message is the sum of the individual
errors:
H 0000 0200
Readback Digital Output Error
H 0000 0100
Temperature Error
H 0000 0080
Overlap Error
H 0000 0004
Encoder Supply Error
H 0000 0002
SIN/COS Channel 2 Error
H 0000 0386