Page 36 / 43
Section 4. Programmers reference
4.8.17. Delete all presets
Description
: This command deletes all the presets from the analog input port.
Format
Example
Command {:AF#<in>@SI=DEL;255}
→ {:af#2@si=DEL;255}
Response (AF DELETED)CrLf
← (AF DELETED)CrLf
Explanation:
The command deletes all the presets.
4.8.18. Clone preset
Description
: This command clones the desired preset to all of the input ports.
Format
Example
Command {:AF#<in>@SI=CL;<PID>}
→ {:af#2@si=CL;1}
Response (AF CLONED)CrLf
← (AF CLONED)CrLf
Legend:
<PID>
Preset ID number
Explanation:
This command is reserved for compatibility reasons.
4.8.19. List presets
Description
: This command reads and lists all the saved presets from the analog VGA
input port.
Format
Example
Command {:AF#<in>@<S/A>I=LIST}
→ {:af#2@si=list}
Response (AF#<in>:<PID>=
<BL>;<LCF>;<FCL>;<LCVS>;
<SCN>;<VSPP>;<HSPP>;
<VPL>;<HPP>;<VSL>;<HSP>;
<FHSP>;<PHS>
;
)CrLf
(AF END)
←
←
(AF#2:1=
3045;1249;1864;3;
0;1;1;
50;495;1200;1600;
2161;23;)CrLf
(AF END)
Legend:
<S/A>:
Affected ports:
S = single selected input
A = all inputs
<PID>
Preset ID number
<BL>:
(8 x 28.6363M) / fhsync
<LCF>:
28.6363M / (256 * fvsync)
<FCL>:
Number of lines in a whole picture
<LCVS>
Number of lines during v.sync
<SCN>
Screen scan type:
0 = progressive
1 = interlaced
<VSPP>
V.sync polarity
0 = negative
1 = positive
<HSPP>
H.sync polarity
0 = negative
1 = positive
<VPL>
Vertical position in lines
<HPP>
Horizontal position in pixels
<VSL>
Vertical size in lines
<HSP>
Horizontal size in pixels
<FHSP>
Full horizontal size in pixels
<PHS>
Phase (0 .. 31)
Explanation:
One preset was saved to the input port 2.