UMX-TP-TX100R
Programmer’s Reference Manual
Section 4. Programmers reference
Page 17 / 43
4.4.2. Change RS-232 baud rate
Description
: The RS-232 baud rate can be set. The command has to be sent with the
earlier baud rate but the response comes with the new baud rate.
Format
Example
Command {RS232BAUD=<rate>}
→ {RS232BAUD=9600}
Response (RS232BAUD=<rate>)CrLf
← (RS232BAUD=9600)CrLf
Explanation:
The device RS-232 port is set to 9600 baud.
Possible settings:
<rate>
Baud rate
9600
9600 baud
19200
19 200 baud
38400
38 400 baud
57600
57 600 baud (default)
115200
115 200 baud
4.4.3. Query RS-232 baud rate
Description:
The RS-232 baud rate can be checked. It works via RS-232 as well, but if it
is used the command has to be sent with the appropriate baud rate.
Format
Example
Command {RS232BAUD=?}
→ {RS232BAUD=?}
Response (RS232BAUD=<rate>)CrLf
← (RS232BAUD=57600)CrLf
Legend:
Please read section
4.4.2
on page
17
.
Explanation:
The device communicates with 57600 baud on the RS-232 port.
4.4.4. Reload factory defaults
Description
: Factory default settings can be reloaded for different functions separately.
Multiple functions can be entered.
Format
Example
Command {
FACTORY=<f1>;<f2>;…;<fx>} → {factory=xpoint;iocards;edidmem}
Response (
FACTORY●<f1>…)CrLf
(FACTORY●<f2>…)CrLf
…
(FACTORY●<fx>…)CrLf
←
←
←
(
FACTORY XPOINT…)CrLf
(FACTORY IOCARDS…)CrLf
(FACTORY EDIDS…)CrLf
Legend:
<f1>, <f2>
are the names of the functions which have to be reset to factory
default. Any number of <fx> can be entered, separated by semicolons.
<fx>
Restores factory settings to
Additional response
XPOINT
Crosspoint table and configuration
none
IONAMES Input and output names
(INAME#1=Input1)
(ONAME#1=Output1)
IOCARDS
All I/O settings for boards currently in the frame
none
EDIDMEM Clear User and Dynamic EDIDs
(DE_OK)
(E_SW_OK)
…
(E_SW_OK)
ALL
Restores all of the factory settings listed above
none
Содержание UMX-TP-TX100R
Страница 1: ...UMX TP TX100R Programmer s Reference Manual ...
Страница 2: ......