![Lightware UMX-TP-TX100R Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/lightware/umx-tp-tx100r/umx-tp-tx100r_programmers-reference-manual_1915399019.webp)
UMX-TP-TX100R
Programmer’s Reference Manual
Section 4. Programmers reference
Page 19 / 43
4.4.9. Restart matrix router
Description
: The extender can be restarted without unplugging power.
Format
Example
Command {RST}
→ {rst}
Response
(Booting…)CrLf
(<name>
●Ready!)CrLf
←
←
(
Booting…)CrLf
(UMX-TP-TX100R Ready!)
Legend:
<name>
is the type of the extender
Explanation:
The extender reboots and sends a message when it is ready.
Info:
The response can be seen only if the connection to the extender is still alive.
4.4.10. View error list
Description
: Shows the basic error list since last boot up.
Format
Example
Command {ELIST=?}
→ {elist=?}
Response (ELIST#<num>
●<elevel>●<code>
●<param>●<occ>
)CrLf
…
(ELIST#<num>
●<elevel>●<code>
●<param>●<occ>
)CrLf
←
←
(ELIST#1 Notice BOOT
p:6 o:1
)
CrLf
…
(ELIST#2 Notice READY
p:0 o:1)
CrLf
Legend:
<num>:
line number
<elevel>:
NOTICE =
Not an error. Initialization information.
WARNING = Possible problem without influencing normal
operation.
MATTER =
Problem that may lead to further errors.
ERROR =
Serious error. Must report to support.
FATAL =
Fatal error. Normal operation is not possible.
<code>:
short name for type of log entry
<param>:
technical parameter
<occ>:
occurrence number for this type of log entry
Explanation:
There are no errors only standard notices that occur on boot up.
Info:
The error list can contain NOTICEs and WARNINGs under normal operation. These
entries do not mean that there is any problem with the matrix!