4.8.3. Set analog timing properties
Description
: This command changes the setup of the analog timing data.
Format
Example
Command {:ANALOG#<in>@<S/A>I=
<PHS>;<FHS>;
<HS>;<VS>;
<HP>;<VP>;}
→ {:analog#2@si=
10;2160;
1600;1200;
455;41;}
Response (DVII#<in>@<S/A>I=
<PHS><FHS>;
<HS>;<VS>;
<HP>;<VP>;
<LCF>;
<FORM>;<VSP>;<HSP>;
<FPS>;
)CrLf
← (ANALOG#2@SI=
10;2160;
1600;1200;
455;41;
1124;
P;-;-;
50;)CrLf
Legend:
<S/A>:
Affected ports:
S = single selected input
A = all inputs
<PHS>
Phase
<FHS>
Full Horizontal Size
<HS>
Horizontal Size
<VS>
Vertical Size
<HP>
Horizontal Position
<VP>
Vertical Position
Info:
The following parameters cannot be set, they only appear in response.
<LCF>
Full Vertical Size (Line Count per Field)
<FORM>
Format: Progressive or Interlaced
<VSP>
Vertical Sync. Polarity
<HSP>
Horizontal Sync. Polarity
<FPS>
Frame Per Sec in Hz
4.8.4. Query analog timing properties
Description
: Check analog timing data of the input ports.
Format
Example
Command {:ANALOG#<in>@<S/A>I=?}
→ {:analog#2@si=?}
Response (ANALOG#<in>@<S/A>I=
<PHS>;<FHS>;
<HS>;<VS>;
<HP>;<VP>;
<LCF>;
<FORM>;<VSP>;<HSP>;<FPS>
)CrLf
← (ANALOG#2@SI=
0;2160;
1600;1200;
455;41;1242;
P;+;+;60;)CrLf
Legend:
Please read section
4.8.3
on page
31
.
4.8.5. Reset analog timing properties
Description
: This command resets the analog timing properties.
Format
Example
Command {:ANALOG#<in>@<S/A>I=RESET}
→ {:analog#2@si=reset}
Response (ANALOG#<in>@<S/A>I=
<PHS>;<FHS>;
<HS>;<VS>;
<HP>;<VP>;<LCF>;
<FORM>;<VSP>;<HSP>;<FPS>)CrLf
← (ANALOG#1@SI=
0;2160;
1600;1200;
455;41;1242;
P;+;+;60;)CrLf
Legend:
Please read section
4.8.3
on page
31
.