Page 14 / 43
Section 4. Programmers reference
4.
Programmers reference
Users can connect to the extender through serial port.
Lightware UMX-TP-TX100R can be controlled with external devices which can
communicate according to the extender protocol.
4.1.
Serial port settings
UMX-TP-TX100R uses RS-232 communication port. D-SUB connector pin assignments
can be found in section
1.6
on page
10
.
The device uses standard RS-232 interface with the following default settings:
57600 Baud, 8 data bit, 1 stop bit, no parity
The serial port baud rate can be changed with protocol command. See section
4.4.2
on
page
17
.
4.2.
Protocol description
The protocol description hereinafter stands for Lightware protocol.
The devices accept commands surrounded by curly brackets - { } - and responds with
data surrounded by round brackets - ( ) - only if a command was successfully executed.
All input commands are converted to uppercase, but respond commands can contain
upper and lower case letters as well.
Legend for control commands:
<in>
=
input number in 1 or 2 digit ASCII format (01,5,07,16 etc.)
<out>
=
output number in 1 or 2 digit ASCII format
<in²>
=
input number in 2 digit ASCII format (01, 02, 10, 12 etc.)
<out²> =
output number in 2 digit ASCII format (01, 02, 10, 12 etc.)
<loc>
=
location number in 1, 2 or 3 digit ASCII format
<id>
=
id number in 1 or 2 digit ASCII format
<id²>
=
id number in 2 digit ASCII format
<italic>
=
italic parameters are optional
CrLf
=
Carriage return, Line feed (0x0D, 0x0A)
●
=
space character (0x20)
→
=
each command issued by the controller
←
=
each response received from the router