background image

 

StoreX

 

Series

  

 

Remote Operation V0712 .doc 

19

  RKi, 26.11.2020 

DISCONTINUED 

1.3.6 

Short Access Operations 

 
The following commands allow extremely short and simple command sequences. When 
using short commands the plates are numbered from 1 to the maximum plate capacity. The 
maximum plate capacity is the value in DM25 (number of levels) multiplied with the value in 
DM29 (number of stackers). The way the plates are numbered can be selected. By default 
the plates are numbered beginning at the lowest level of stacker 1 to the top level of stacker 
1, continuing at the lowest level of stacker 2 ending at the top level of stacker 2 (Vertical 
Mode). The optional numbering starts at the lowest level of stacker 1, lowest level of stacker 
2, second level of stacker 1, second level of stacker 2, third level of stacker 1 etc. (Horizontal 
Mode). 
 

 

Command 

Response 

Import plate n 

WR 

sp

 DM10

 sp

 n 

cr

 

OK 

cr lf

 

Export plate n 

WR 

sp

 DM10

 sp

 -n 

cr

 

OK 

cr lf

 

Export plate n (unsigned alternative) 

WR 

sp

 DM15

 sp

 n 

cr

 

OK 

cr lf

 

 

 

 

Select Vertical Numbering Mode (default) 

ST 

sp

 1604

 cr

 

OK 

cr lf

 

Select Horizontal Numbering Mode 

RS 

sp

 1604

 cr

 

OK 

cr lf

 

 
One Short Access Command can be sent while the prior access is being executed. This 
second command is stacked and executed after termination of the first command. 
 
 

1.4 

Handling Status / Error Messages 

Error Commands are used when the handling detects an internal error (e.g. when loading a 
plate to an occupied location). In case of error the Error Flag (1814) is set from ‘0’ to ‘1’. The 
exact cause of an error can be found in the data memory 200 (DM200). For each type of 
error an error code is set in DM200. The list below shows the meaning of the error code. 
Errors are read by reading the content of DM200. On a time-out, first the Error Flag is read 
(RD 1814). Then DM200 is read in order to find the cause of error. An error is reset by 
sending the Reset Command (ST 1900). 
 
Errors DM200=1xx are Import Plate Errors, errors DM200=2xx are Export Plate Errors. 
 

 

Command 

Response 

Read Error Flag (default =0) 

RD 

sp

 1814 

cr

 

cr lf

 

Read Error Code 

RD 

sp

 DM200 

cr

 

cr lf

 

 
 
The following tables will list the StoreX status messages.  
 

Error 

Description 

Code 

General Handling Error 

Handling action could not be performed in 
time. 

00001 

cr lf

 

Gate Open Error 

Gate could not reach upper position or  
Gate did not reach upper position in time 

00007 

cr lf

 

Gate Close Error 

Gate could not reach lower position or Gate 
did not reach lower position in time 

00008 

cr lf

 

General Lift Positioning Error  Handler-Lift could not reach desired level 

position or 
does not move 

00009 

cr lf

 

User Access Error 

Unauthorized user access in combination 

00010 

cr lf

 

Содержание StoreX BT

Страница 1: ...e Operation for StoreX Precision Incubator Series DISCONTINUATION This Interface is no longer supported Do not use for new development STX40 STX100 STX200 STX500 STX1000 IC HC HR DC DR DF SA BT IT STP...

Страница 2: ...ot follow the instructions given in this manual LiCONiC does not take any responsibility for injuries or damages caused by the LiCONiC product Contact Address LiCONiC AG Industriestrasse 8 FL 9493 Mau...

Страница 3: ...RKi 26 11 2020 DISCONTINUED Table of Contents 1 Remote Operation 5 1 1 RS 232 Serial Port Configuration 5 1 2 Command Transmission Procedure 5 1 3 Commands 11 1 4 Handling Status Error Messages 19 1 5...

Страница 4: ...ies Remote Operation V0712 doc 4 RKi 26 11 2020 DISCONTINUED History Page Document Change History Date Version Changes Author 26 11 2020 V7 12 Discontinuation This interface is not Supported anymore R...

Страница 5: ...al port is reset by sending a Brake Signal The specification of the Brake Signal is given below In most cases the Brake Signal can be omitted The example program shows how a Brake Signal can be implem...

Страница 6: ...mand PC Controller Resonse PC Controller 1 2 5 Command Syntax For communication only a few commands are required A command is an ASCII string which is sent to the controller Response is an ASCII strin...

Страница 7: ...ackStr pN INTEGER s STRING STRING CONST tries 2 VAR i n m err INTEGER w WORD s0 s1 STRING c kp CHAR BEGIN IF NOT kbdEsc THEN BEGIN EmptyAux pN i 1 s0 s m Pos s0 IF m 0 THEN BEGIN Delete s0 m 1 s1 Copy...

Страница 8: ...NG BEGIN Str rel sR STX_Set STX_ReadBackStr pN ST sR END FUNCTION KV_Reset pN rel INTEGER STRING VAR sR STRING BEGIN Str rel sR STX_Reset STX_ReadBackStr pN RS sR END FUNCTION STX_Read pN rel INTEGER...

Страница 9: ...lf Write Protected Error Unauthorized Access E4 cr lf Base Unit Error Unauthorized Access E5 cr lf 1 2 8 List of Operations Operations are physically executable commands Operations are triggered by on...

Страница 10: ...ready to accept commands or 1 handling ready command may be sent In its idle status the handling sets the Ready Bit to 1 Command Response Read Ready Bit RD sp 1915 cr x cr lf When polling the Ready Bi...

Страница 11: ...5 sp n cr OK cr lf Set Handler Stacker Pitch WR sp DM23 sp p cr OK cr lf Open Gate2 ST sp 1901 cr OK cr lf Close Gate3 ST sp 1902 cr OK cr lf Terminate Access ST sp 1903 cr OK cr lf Import plate to m...

Страница 12: ...ified slot Note that stacker levels are numbered starting at the bottom level upwards Bottom level is 1 The Activate Handler Command initializes the handling Use the Activate Handler Command after col...

Страница 13: ...OK cr lf Position rotation at slot 2 WR sp DM5 sp 10 cr OK cr lf Select level 10 in stacker ST sp 1904 cr OK cr lf Import Command to start import process To export a plate form level 22 in the stacke...

Страница 14: ...o Way Communication Activation Flag default 0 RS sp 1200 cr OK cr lf Read Flag Send Handling Progress Status SPX default 0 RD sp 1201 cr x cr lf Set Flag Send Handling Progress Status SPX default 0 ST...

Страница 15: ...1611 cr OK cr lf Read Wait Plate selection RD sp 1612 cr x cr lf Wait Plate on stop at x fer station until plate present resp x fer station is free ST sp 1612 cr OK cr lf Wait Plate off do not check...

Страница 16: ...Stacker position default 940 RD DM81 cr ddddd cr lf Read Handler Transfer Station position default 3500 RD DM82 cr ddddd cr lf Set Handler z Offset WR DM20 sp d cr OK cr lf Set Handler dz Pick Palce M...

Страница 17: ...M for plate transfer Daughter Plate ST 1105 cr OK cr lf Select upper level on TPM for plate transfer Mother Plate RS 1105 cr OK cr lf Read lift transfer height for plate transfer at TPM RD DM41 cr ddd...

Страница 18: ...ated in DM251 DM499 DM251 represents cassette location number 1 DM252 cassette location number 2 A total of 250 cassettes can be configured Each entry of the Cassette Configuration Table contains the...

Страница 19: ...s stacked and executed after termination of the first command 1 4 Handling Status Error Messages Error Commands are used when the handling detects an internal error e g when loading a plate to an occu...

Страница 20: ...er Error Shovel could not reach outer position at transfer level during Import Plate procedure 00102 cr lf Import Plate Lift Transfer Error Lift did not reach upper pick position at transfer level dur...

Страница 21: ...r place position at transfer level during Export Plate procedure 00207 cr lf Export Plate Shovel Transfer Inner Error Shovel could not reach inner position at transfer level during Export Plate proced...

Страница 22: ...EDURE STX_WaitReadyTrace portNbr INTEGER VAR c CHAR x y err INTEGER n WORD BEGIN WRITE x WhereX y WhereY DelayMs 300 WHILE STX_Read prtNbr 1915 0 AND NOT KeyPressed DO BEGIN DelayMs 100 GotoXY x y Val...

Страница 23: ...StoreX Series Remote Operation V0712 doc 23 RKi 26 11 2020 DISCONTINUED...

Страница 24: ...or most StoreX commands is given below Use this procedure after initializing the instrument only PROCEDURE STX_DoPlate pN slot level INTEGER command STRING BEGIN IF NOT KeyPressed THEN BEGIN STX_WaitR...

Страница 25: ...S Nbr Direct Commands 1 Monitor Flags 2 Macros 3 Teach Positioning Times 4 Random Positioning 5 Random Access Cycles 6 Random Fast Access 7 Quit 0 ____________________________________________________...

Страница 26: ...message 0 means inactive the status message 1 means active Code Status Flag Comment P0 0000 0 initiator of carrousel Pn 0001 Position initiator of carrousel GtClse 0002 Gate closed switch GtOpen 0003...

Страница 27: ...d R Reset Handling Controller Q Exit macro menu Accs Carrousel access remote or manual Ready Ready Bit 2 1 4 Teach Positioning Times Program to measure positioning times of the carrousel The program s...

Страница 28: ...r then 0 4 seconds compared with the calibrated positioning time is observed a positioning error is assumed and monitored 2 1 7 Random Fast Access Program for positioning the carrousel randomly includ...

Отзывы: