46
THE INDOOR UNIT INSTALLATION
ENGLISH
CAUTION
!
The Power cord connected to the unit
should be selected according to the
following specifications.
1
1
3
3
2
2
Connecting Cable
Clamp Cord
Terminal Block
3
Secure the cable onto the Control panel
with the Clamp cord.
4
If indoor unit's setting is needed, loosen
No.3 screw and lift up the PCB. (option:
usage of bottom vanes, limit angle of top
vane)
DIP
S/W
Description
S/W OFF
S/W ON
S/W 5
Install
scene
Exposed
Half
Concealed
S/W 7
Vane
Top+Bottom
vane
Top vane
only
Connect the cable to the indoor unit by
connecting the wires to the terminals on the
control board individually according to the
outdoor unit connection. (Ensure that the color
of the wires of the outdoor unit and the
terminal No. are the same as those of the
indoor unit.)
Insert the connecting cable through the bot-
tom side of indoor unit and connect the cable.
(1) Open the Decor
(2) Unscrew the screw of C/Box
(3) Slide up the Metal Plate Cover
(4) Connect the connecting cable
(5) After complete connect the cables, should
assemble the Metal Plate Cover by screw.
Decor
Power
Power
connecting cable
connecting cable
Power
connecting cable
1(L) 2(N) 3(C)
1(L)
2(N)
3
Terminal Block of Indoor Unit
Outdoor
1
Loosen No 1, 2 screws of control box
cover.
2
Connect the cable to the Terminal block as
below diagram
Содержание UM36FH