18
ENGLISH
INSTALLATION PLACES
* The feature can be changed according to type of model.
More Than
200
More Than
100
More Than
100
More Than
2 300
More Than
500
More Than
500
More Than
200
More Than
1 500
NOTE
The gap between the indoor unit and ceiling is needed more than 200 mm for disassemble
the air filter.
[Wall Mounted]
- There should not be any heat or steam near the unit.
- Select a place where there are no obstacles around of the unit.
- Make sure that condensation drainage can be conveniently routed away.
- Do not install near a doorway.
- Ensure that the interval between a wall and the left (or right) of the unit is more than 100 mm.
The unit should be installed as high as possible on the wall, allowing a minimum of 200 mm
from ceiling.
- Use a metal detector to locate studs to prevent unnecessary damage to the wall.
(Unit: mm)