Code
Item
Detail
Remark
12
Value #2
Note
Lower limit of setting range(FCU is not equipped)
Default
16 °C
Range
16 ~ 18 °C
13
Function
Setting air temperature in heating mode
Description
Adjusting range of 'Setting Air Temperature' in heating mode
Value #1
Note
Upper Limit of setting range
Default
30 °C
Range
24 ~ 30 °C
Value #2
Note
Lower Limit of setting range
Default
16 °C
Range
16 ~ 22 °C
14
Function
Setting Heating flow temperature in heating mode
Description
Adjustin range of 'Setting Heating flow Temperature' in
heating mode
Value #1
Note
Upper Limit of setting range
Default
57 °C
Range
35 ~ 57 °C
Value #2
Note
Lower Limit of setting range
Default
15 °C (*20 °C)
Range
15 ~ 34 °C (*20 ~ 34 °C)
15
Function
Setting DHW tank heating flow temperature for
Sanitary water heating
Description
Adjusting range of 'Setting DHW tank heating flow Temperature'
in Domestic hot water tank heating mode
Value #1
Note
Upper Limit of setting range
Default
50 °C
Range
50 ~ 80 °C
Value #2
Note
Lower Limit of setting range
Default
40 °C
Range
30 ~ 40 °C
18
Function
Screed drying mode
Description
After installing water pipes for under floor heating, user can select
screed drying mode for curing the cement
Value #1
Note
Default
01
Range
00 ~ 01
Value #2
Note
Default
-
-
Range
-
'Setting DHW
tank heating flow
Temperature' is
used when user
wants to set water
temperature of
Domestic hot
water tank.
00: Screed drying mode is not connected and not used.
01:Remote air sensor is connected and used.
'Setting air
temperature' is
used when user
wants to set
target
temperature by
room air
temperature.
'Setting Heating
flow temperature'
is used when
user wants to set
target tempera-
ture by
Heating flow
(from the unit)
temperature.
* : Electric heater
is not used
System Set-Up