System Set-Up
• Function Code 23, 24, and 25
: Setting Weather-dependent operation
Weather-dependent operation is that the product automatically adjusts target temperature (leaving
water or room air) according to the outdoor air temperature.
- Value #1 and Value #2 of Function Code 23 : range of outdoor air temperature
- Value #1 and Value #2 of Function Code 24 : range of auto-adjustable target room air temperature
- Value #1 and Value #2 of Function Code 25 : range of auto-adjustable target leaving water tem-
perature
Note :
Weather-dependent operation is applied for heating mode only.
Value #1 of
Function Code 23
Auto-Adjustable
Target Temperature
Outdoor
air temperature
Temperature profile
of Weather-dependent
operation
Value #2 of
Function Code 23
Value #1 of
Function Code
24 or 25
Value #2 of
Function Code
24 or 25
88
Air-to-Water Heat Pump
Содержание Therma V AHUW096A2
Страница 97: ......