18
COMMUNICATION KIT INSTALLATION
E
N
G
L
IS
H
Controller Setting Method
If you want to run the Fan(L/M/H) in Heating Mode - defrosting condition, you should set the dip
switch 4 to "On"(As shown below)
• PCB output signal(According to the dip switch 4 setting)
Dip switch setting
(Main PCB)
* Setting : Black
[Default setting]
- . No 1/2/3/5/6/7/8 : Off
- . No 4 : On
1
2
3
4
5
6
7
8
ON
1
2
3
4
5
6
7
8
Output Signal
Condition
Thermal
On/Off
Fan L/M/H
Defrost
Heating
Mode
Dip switch Off
Off
Off
Off
Off
Off
Cooling Mode
Off or On
On
Off
Off
Fan Mode
Off
On
Off
Off
Heating Mode
Off or On
Off or On
Off
On
Heating Mode – Preheating
On
Off
Off
On
Heating Mode – Defrosting
On
Off
On
On
Auto Mode
The Same as Cooling or Heating Mode
Dip switch On
Off
Off
Off
Off
Off
Cooling Mode
Off or On
On
Off
Off
Fan Mode
Off
On
Off
Off
Heating Mode
Off or On
On
Off
On
Heating Mode – Preheating
On
On
Off
On
Heating Mode – Defrosting
On
On
On
On
Auto Mode
The Same as Cooling or Heating Mode