36
TROUBLESHOOTING
E
N
G
L
IS
H
- Error checking : The errors may be checked on LED of the display parts of wired remote con-
troller and the LED of the controller of outdoor device.
Code
Contents
Operation
State
Error Display
Cable Remote
Controller
Outdoor Device
Red LED Green LED
21 IGBTM Fault Error
Stop
CH21
Flashing
2 times
Flashing
1 time
22 CT 2 Error (Input of Over-Current)
Stop
CH22
Flashing
2 times
Flashing
2 times
23 DC Link Error (High/Low DC Voltage)
Stop
CH23
Flashing
2 times
Flashing
3 times
25 Outdoor Unit Input Voltage High/Low Voltage
Stop
CH25
Flashing
2 times
Flashing
5 times
26 DC Comp Position Detection Error
Stop
CH26
Flashing
2 times
Flashing
6 times
27 PSC/PFC Over-Current Error (HW)
Stop
CH27
Flashing
2 times
Flashing
7 times
29 Comp Phase Over-Current Error
Stop
CH29
Flashing
2 times
Flashing
9 times
32 D-Pipe Overheating Error (INV Comp)
Stop
CH32
Flashing
3 times
Flashing
2 times
40 Outdoor Unit Inverter Compressor CT Sensor Fault
Stop
CH40
Flashing
4 times
-
41 D-Pipe Sensor Error (INV Comp)
Stop
CH41
Flashing
4 times
Flashing
1 time
43 High pressure Sensor Error
Stop
CH43
Flashing
4 times
Flashing
3 time
44 Outdoor Inlet Sensor Error
Stop
CH44
Flashing
4 times
Flashing
4 times
45 Cond. Pipe Sensor Error
Stop
CH45
Flashing
4 times
Flashing
5 times
46 Suction Pipe Sensor Error
Stop
CH46
Flashing
4 times
Flashing
6 times
48 Cond. Out-Pipe Sensor Error
Stop
CH48
Flashing
4 times
Flashing
8 times
51 Over-Capacity Connection Error
Stop
CH51
Flashing
5 times
Flashing
1 time
53 Communication Error between Outdoor Device
⇔
Indoor Device
Stop
CH53
Flashing
5 times
Flashing
3 times
54 Open and Reverse Phase Error
Stop
CH54
Flashing
5 times
Flashing
4 times
60 EEPROM Check Sum Error
Stop
CH60
Flashing
6 times
-
61 Outdoor Device Pipe Overheating Error
Stop
CH61
Flashing
6 times
Flashing
1 time
62 Heat-sink Overheating Error
Stop
CH62
Flashing
6 times
Flashing
2 times
65 Heat-sink Sensor Error
Stop
CH65
Flashing
6 times
Flashing
5 times
67 Outdoor BLDC Fan Lock Error
Stop
CH67
Flashing
6 times
Flashing
7 times
71 Converter CT Sensor Error of Outdoor Unit
Stop
CH71
Flashing
7 times
Flashing
1 time
73 PSC/PFC Over-Current Error (SW)
Stop
CH73
Flashing
7 times
Flashing
3 times